CNC All models error codes
Codes
- SP9049Error codeIn differential speed mode, the speed of the other spindle converted to the speed of the local spindle has exceeded the allowable limit (the differential speed is calculated by multiplying the speed of the other spindle by the gear ratio)
- SP9050Error codeIn spindle synchronization, the speed command calculation value exceeded the allowable limit (the motor speed is calculated by multiplying the specified spindle speed by the gear ratio)
- SP9051Error codeInput voltage drop was detected. (Power Supply (PS) alarm indication: 4) (Momentary power failure or poor MC contact)
- SP9052Error codeAn abnormality is detected in the interface between the CNC and spindle amplifier (the ITP signal stopped)
- SP9053Error codeAn abnormality is detected in the interface between the CNC and spindle amplifier the ITP signal stopped)
- SP9054Error codeAn overload current was detected
- SP9055Error codeThe power line state signal of the magnetic contactor for selecting a spindle or output is abnormal
- SP9056Error codeThe internal cooling fan stopped
- SP9057Error codeAn overload was detected in the regenerative resistance. (Power Supply (PS) alarm indication: H) Thermostat operation or short-time overload was detected. The regenerative resistor was disconnected, or an abnormal resistance was detected
- SP9058Error codeThe temperature of the radiator of the Power Supply (PS) has increased abnormally. (Power Supply (PS) alarm indication: 3)
- SP9059Error codeThe internal cooling fan for the Power Supply (PS) stopped. (Power Supply (PS) alarm indication: 2)
- SP9061Error codeThe error between the semi-closed and full-closed sides when the dual position feedback function is used is too large
- SP9065Error codeThe move distance is too long when the magnetic pole is confirmed (synchronization spindle)
- SP9066Error codeAn error was found in communication between spindle amplifiers (connector JX4)
- SP9069Error codeIn the state in which safety speed monitoring was enabled, the system detected that the motor speed exceeded the safety speed or detected an error during a free-run stop
- SP9070Error codeThe axis data is abnormal. An error was detected in an axis number check
- SP9071Error codeThe safety parameter is abnormal. An abnormality is detected in the safety parameter
- SP9073Error codeThe motor sensor feedback signal is not present (connector JYA2)
- SP9074Error codeAn error was detected in a CPU test
- SP9075Error codeAn error occurred in a spindle amplifier CRC test
- SP9079Error codeAn error was detected in a spindle amplifier initial test
- SP9080Error codeDuring inter-Spindle Amplifier communication, an alarm was generated on the remote Spindle Amplifier
- SP9081Error codeThe one-rotation signal of the motor sensor cannot be correctly detected(connector JYA2)
- SP9082Error codeThe one-rotation signal of the motor sensor is not generated(connector JYA2)
- SP9083Error codeAn irregularity was detected in a motor sensor feedback signal(connector JYA2)
- SP9084Error codeThe spindle sensor feedback signal is not present(connector JYA4)
- SP9085Error codeThe one-rotation signal of the spindle sensor cannot be correctly detected(connector JYA4)
- SP9086Error codeThe one-rotation signal of the spindle sensor is not generated(connector JYA4)
- SP9087Error codeAn irregularity was detected in a spindle sensor feedback signal(connector JYA4)
- SP9088Error codeThe external radiator cooling fan stopped
- SP9089Error codeSubmodule SM (SSM) error (synchronous spindle)
- SP9090Error codeAbnormal rotation of the synchronous spindle motor was detected
- SP9091Error codeCount error of the magnetic pole position of the synchronous spindle motor
- SP9092Error codeThe motor speed exceeds the acceleration level corresponding to the velocity command
- SP9110Error codeCommunication error between Spindle Amplifier and Power Supply (PS)
- SP9111Error codeLow Power Supply (PS) control power supply voltage (Power Supply (PS) indication = 6)
- SP9112Error codeExcessive Power Supply (PS) regenerative power (Power Supply (PS) indication = 8)
- SP9113Error codeStopped the external radiator cooling fan for Power Supply (PS) (Power Supply (PS) indication = A)
- SP9120Error codeCommunication data alarm
- SP9121Error codeCommunication data alarm
- SP9122Error codeCommunication data alarm
- SP9123Error codeSubmodule SW (SSW) error (spindle switching)
- SP9131Error codeSpindle adjustment function alarm
- SP9132Error codeSerial data error
- SP9133Error codeData transfer error
- SP9134Error codeSoft phase
- SP9135Error codeThe motor position exceeded the safety speed zero monitoring width
- SP9137Error codeDevice communication error
- SP9139Error codePulse error
- SP9140Error codeCount error