CNC All models error codes
Codes
- SP1247Error codeA communication data error was detected on the CNC
- SP1969Error codeAn error occurred in the spindle control software
- SP1970Error codeInitialization of spindle control ended in error
- SP1971Error codeAn error occurred in the spindle control software
- SP1972Error codeAn error occurred in the spindle control software
- SP1974Error codeAn error occurred in the spindle control software
- SP1975Error codeAn position coder error was detected on the analog spindle
- SP1977Error codeAn error occurred in the spindle control software
- SP1978Error codeA time-out was detected during communications with the serial spindle amplifier
- SP1979Error codeThe communications sequence was no longer correct during communications with the serial spindle amplifier
- SP1980Error codeDefective SIC-LSI on serial spindle amplifier
- SP1981Error codeAn error occurred during reading of the data from SIC-LSI on the analog spindle amplifier side
- SP1982Error codeAn error occurred during reading of the data from SIC-LSI on the serial spindle amplifier side
- SP1984Error codeAn error occurred during re-initialization of the spindle amplifier
- SP1986Error codeAn error occurred in the spindle control software
- SP1987Error codeDefective SIC-LSI on the CNC
- SP1988Error codeAn error occurred in the spindle control software
- SP1989Error codeAn error occurred in the spindle control software
- SP1998Error codeAn error occurred in the spindle control software
- SP1999Error codeAn error occurred in the spindle control software
- SP9001Error codeThe internal temperature of the motor exceeds the specified level. The motor is used in excess of the continuous rating, or the cooling component is abnormal
- SP9003Error codeThe Power Supply (PS) becomes ready (“00” is indicated), but the DC link voltage is too low in the Spindle Amplifier. The fuse in the DC link section in the Spindle Amplifier is blown. (The power device is damaged or the motor is ground-fault.)
- SP9004Error codeThe Power Supply (PS) found a missing power supply phase. (Power Supply (PS) alarm E)
- SP9006Error codeThe temperature sensor of the motor is disconnected
- SP9007Error codeThe motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.)
- SP9009Error codeThe temperature in the power semiconductor cooling radiator is abnormally high
- SP9010Error codeA drop in the input power voltage in the spindle amplifier is detected
- SP9011Error codeOvervoltage of the DC link section of the Power Supply (PS) was detected. (Power Supply (PS) alarm indication: 7) Power Supply (PS) selection error. (The maximum output specification of the Power Supply (PS) is exceeded.)
- SP9012Error codeThe motor current is abnormally high. A motor-specific parameter does not match the motor model. Poor motor insulation
- SP9013Error codeAbnormality in an Spindle Amplifier control circuit component is detected. (Internal RAM is abnormal.)
- SP9015Error codeThe switch sequence in spindle switch/output switch operation is abnormal. The switching MC contact status check signal and command do not match
- SP9016Error codeAbnormality in an Spindle Amplifier control circuit component is detected. (RAM for external data is abnormal.)
- SP9017Error codeAbnormality in spindle amplifier ID data is detected
- SP9018Error codeAbnormality in an Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.)
- SP9019Error codeAbnormality in an Spindle Amplifier component is detected. (The initial value for the U phase current detection circuit is abnormal.)
- SP9020Error codeAbnormality in an Spindle Amplifier component is detected. (The initial value of the V phase current detection circuit is abnormal.)
- SP9022Error codeA spindle amplifier overload current was detected
- SP9024Error codeThe CNC power is turned off (normal power-off or broken cable). An error is detected in communication data transferred to the CNC
- SP9027Error codeThe spindle position coder (connector JYA3) signal is abnormal
- SP9029Error codeExcessive load has been applied continuously for a certain period of time. (This alarm is issued also when the motor shaft has been locked in the excitation state.)
- SP9030Error codeOvercurrent is detected in Power Supply (PS) main circuit input. (Power Supply (PS) alarm indication: 1) Unbalanced power supply. Power Supply (PS) selection error (The maximum Power Supply (PS) output specification is exceeded.)
- SP9031Error codeThe motor cannot rotate at a specified speed. (A level not exceeding the SST level for the rotation command has existed continuously.)
- SP9032Error codeAbnormality in an Spindle Amplifier control circuit component is detected. (The LSI device for serial transfer is abnormal.)
- SP9033Error codeThe DC power voltage in the power circuit is insufficient when the magnetic contactor is turned on. (Power Supply (PS) alarm indication: 5) (Such as open phase and defective charging resistor)
- SP9036Error codeAn error counter overflow occurred
- SP9037Error codeThe setting of the parameter for the number of pulses in the speed detector is incorrect
- SP9041Error code1 The 1-rotation signal of the spindle position coder (connector JYA3) is abnormal. 2 Parameter setting error
- SP9043Error codeThe differential speed position coder signal (connector JYA3S) in the submodule SW is abnormal
- SP9046Error codeThe 1-rotation signal in threading is abnormal
- SP9047Error codeThe A/B phase signal of the spindle position coder (connector JYA3) is abnormal. The relationship between the A/B phase and 1-rotation signal is incorrect (Pulse interval mismatch)