Codes
- IE0003Error codeThe malfunction prevention function detected that stored stroke check 2 on the positive side was exceeded
- IE0004Error codeThe malfunction prevention function detected that stored stroke check 2 on the negative side was exceeded
- IE0005Error codeThe malfunction prevention function detected that stored stroke check 3 on the positive side was exceeded
- IE0006Error codeThe malfunction prevention function detected that stored stroke check 3 on the negative side was exceeded
- IE0007Error codeThe malfunction prevention function detected the command in which a value exceeding the maximum speed was specified
- IE0008Error codeThe malfunction prevention function detected the acceleration/deceleration error
- IE0009Error codeThe malfunction prevention function detected the displacement of a machine coordinate in the check point
- IO1001Error codeThe resident-type file system could not be accessed as an error occurred in the resident-type file system
- IO1002Error codeThe file could not be accessed as an error occurred in the CNC file system
- K70MError codeMitsubishi Heavy Indus- tries Machine Tool
- LC495MError codeMitsubishi Heavy Indus- tries Machine Tool
- LK511Error code
- M52Error codeFener milini belli bir konuma döndürür ve kilitler / C eksenini kilitler (S: döndürme açısı)
- n1Error codeIndicates the No. of slot to which the expansion unit with the communication error or diagnostic alarm is
- n2Error codeIndicates the alarm No. of the slot where the communication error or diagnostic alarm is occurring (in hexa-
- odu8Error code
- OH0700Error codeCNC cabinet overheat
- OH0701Error codePCB cooling fan motor abnormality
- OH0704Error codeT Spindle overheat due to detection of changes in the spindle speed 1) When the cutting load is large, offload the cutting conditions. 2) Check if the cutting tool became dull. 3) Check if the spindle amplifier malfunctions
- OSA405Error codeMitsubishi Electric
- OT0506Error codeThe stroke limit switch in the positive direction was triggered. This alarm is generated when the machine reaches the stroke end. When this alarm is not generated, feed of all axes is stopped during automatic operation. During manual operation, only the feed of the axis on which the alarm occurred is stopped
- OT0507Error codeThe stroke limit switch in the negative direction was triggered. This alarm is generated when the machine reaches the stroke end. When this alarm is not generated, feed of all axes is stopped during automatic operation. During manual operation, only the feed of the axis on which the alarm occurred is stopped
- PC004Error code
- PC030Error code
- PC050Error code
- PC051Error code
- PC060Error code
- PC097Error code
- PC501Error code
- PW0001Error codeThe X address of the PMC could not be assigned correctly. This alarm may occur in the following case: 1) During the setting of parameter No. 3013, the X address could not be assigned correctly for the deceleration dog (*DEC) for a return to the reference position
- PW0002Error codeThe address to assign the axis signal is incorrect. This alarm may occur in the following case: 1) The parameter No.3021 setting is incorrect
- PW0003Error codeThe address to assign the spindle signal is incorrect. This alarm may occur in the following case: 1) The parameter No.3022 setting is incorrect
- PW0006Error codeThe malfunction prevention function detected an alarm to require the power off
- PW1102Error codeThe parameter for setting slope compensation is incorrect. This alarm occurs in the following cases: 1) When the size relationship between the slope compensation point Nos. is incorrect 2) When the slope compensation point is not located between the most negative side and most positive side of pitch error compensation 3) When the compensation per compensation point is too small or too great
- RL40NError codeRenishaw
- S01Error codeName or "Servo alarm"
- S03Error codeName or "Servo alarm"
- S04Error codeName or "Servo alarm"
- SP0752Error codeThis alarm is generated if the system does not properly terminate a mode change. The modes include the Cs contour control, spindle positioning (T series), rigid tapping, and spindle control modes. The alarm is activated if the spindle control unit does not respond correctly to the mode change command issued by the NC
- SP0754Error codeAn abnormal load was detected in a spindle motor. The alarm can be canceled by RESET
- SP1221Error codeThe spindle No. and the motor No. are incorrectly matched
- SP1225Error codeA CRC error (communications error) occurred in communications between the CNC and the serial spindle amplifier
- SP1226Error codeA framing error occurred in communications between the CNC and the serial spindle amplifier
- SP1227Error codeA receive error occurred in communications between the CNC and the serial spindle amplifier
- SP1228Error codeA communications error occurred between the CNC and the serial spindle amplifier
- SP1229Error codeA communications error occurred between serial spindle amplifiers (motor Nos. 1 and 2, or motor Nos. 3-4)
- SP1233Error codeThe error counter/speed instruction value of the position coder overflowed
- SP1241Error codeThe D/A converter for controlling analog spindles is erroneous
- SP1245Error codeA communication data error was detected on the CNC
- SP1246Error codeA communication data error was detected on the CNC