- E1AError codeFallen below lower limit value in measuring channel "slewing angle 1". slew below allowed range
- E1CError codeFallen below lower limit value in measuring channel "luffing jib angle"
- E2AError codeUpper limit value in measuring channel "slewing angle 1" has been exceeded slew above allowed range
- E2CError codeUpper limit value in measuring channel "luffing jib angle" has been exceeded
- E05Error code• Length sensor adjustment has changed, e.g. the cable slid off the length sensor reel
- E07Error codeFaulty acknowledgment by the overload relay of the LMI board. Relay should be energized but 2nd contact is indicated off, or the 2nd contact is indicated on while the relay should be deenergized
- E11Error codeFallen below lower limit value for measuring channel "length main boom"
- E12Error codeFallen below the lower limit value in the measuring channel "pressure piston side"
- E13Error codeFallen below lower limit value in the measuring channel "pressure rod side"
- E14Error codeFallen below lower limit value in measuring channel "force"
- E15Error codeFallen below lower limit value in measuring channel "angle main boom"
- E16Error codeFallen below lower limit value in measuring channel "angle 2"
- E17Error codeFallen below lower limit value "length telescope I (+II)"
- E18Error codeFront outrigger overloaded
- E19Error codeReference and/or supply voltage defective
- E21Error codeUpper limit value for measuring channel "length telescopic boom" exceeded
- E22Error codeUpper limit value in measuring channel "pressure piston side" has been exceeded
- E23Error codeUpper limit value in measuring channel "pressure rod side" has been exceeded
- E25Error codeUpper limit value in measuring channel "angle main boom" exceeded
- E31Error codeError in the system program
- E32Error codeError in the power supply
- E37Error codeError in the logical program flow
- E41Error codeError in the internal write/read memory (RAM) of the computer component 80C537
- E42Error codeError in the external write/read memory, 1st part (RAM)
- E43Error codeError in the write/read memory, (RAM)
- E45Error codeRedundancy error in the A/D conversion
- E46Error codeError in the A/D converter uPD 7004 of the processor board
- E47Error codeError in the monitored write/ read memory. The CRC verification of the monitored write/read memory provides an incoherent result
- E48Error codeCyclic RAM test: error in the internal write/read memory (RAM) of the computer component 80C537
- E51Error codeError in the crane data file
- E52Error codeError in load chart file
- E53Error codeWrong setup of min. analog inputs length1, angle1, pressure1
- E56Error codeError in crane data file
- E57Error codeError in buffered data file
- E58Error codeError in the serial analog data EEPROM
- E61Error codeError in the CAN bus data transfer for all CAN units
- E62Error codeError in the can bus data transfer of the pressure transducer sensor unit
- E63Error codeError in the can bus pressure transducer sensor unit
- E64Error codeError in the can bus data transfer of the length/angle sensor unit
- E65Error codeError in the can bus length/angle sensor unit
- E66Error codeError in the data of the digtal I/O MENTOR
- E67Error codeError in the can bus data transfer of the digtal I/O external module
- E80Error codeError in piston-side pressure transducer
- E81Error codeError in rod-side pressure transducer
- E85Error codeError in the radius determination
- E91Error codeNo data trans- mission form the console to the central unit
- E92Error codeError in the data transmission from console to central unit
- E93Error codeError in the data transmission from the central unit to the console
- E94Error codeNo data trans- mission from the central unit to the console