Western Digital depolama sistemi san nas All models error codes
Codes
- 4tError code4th error log data structure
- 5tError code5th error log data structure
- 6Error codeMaximum recommended continuous operating temperature. This is a one byte 2’s complement number that allows a range from -127°C to +127°C to be specified. 80h is an invalid value. This is a fixed value
- 7Error codeMaximum temperature limit. This is a one byte 2’s complement number that allows a range from -127°C to +127°C to be specified. 80h is an invalid value. This is a fixed value
- 8Error codeQWord
- 9Error codeBit 0 : Segment Initialized Flag If this bit is set to 1, an SCT Write Same command write to all LBAs of the drive has completed without error. This bit shall be cleared to 0 when any user LBA is written, even if write cache is enabled. This bit is else cleared if the capacity of the drive is changed via SETMAX, SETMAX EXT or DCO. This bit is preserved through a power cycle. Bit 1-31 : Reserved
- 40Error codeWord
- 47Error codeCurrent LBA of SCT command execution in background. If there is no command currently executing in the background, this field is undefined
- 54Error codeNumber of current cylinders
- 55Error codeNumber of current heads
- 56Error codeNumber of current sectors per track
- 57-58Error codeCurrent capacity in sectors Word 57 specifies the low word of the capacity
- 59Error codeSanitize capabilities and Current Multiple setting. Bit assignments 15 (=0) The BLOCK ERASE EXT command is supported 14 (=1) The OVERWRITE EXT command is supported 13 (=0or1) The CRYPTO SCRAMBLE EXT command is supported 12 (=1) The Sanitize Device Feature Set is supported 11(=1) The commands allowed during a sanitize operation 10-9 (=0) Reserved 8 1= Multiple Sector Setting is Valid 7-0 xxh = Current setting for number of sectors
- 84Error codeCommand set/feature supported extension 15-14 (=01) Word 84 is valid 13 (=1) IDLE IMMEDIATE with UNLOAD FEATURE supported 12-11 (=0) Obsolete 10 (=0) Obsolete 9 (=0) Obsolete 8 (=1) World wide name supported 7 (=0) WRITE DMA QUEUED FUA EXT command supported 6 (=1) WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands supported 5 (=1) General Purpose Logging feature set supported 4 (=0) Streaming feature set supported 3 (=0) Media Card Pass Through Command feature set supported 2 (=0) Media serial number supported 1 (=1) SMART self-test supported 0 (=1) SMART error logging supported
- 87Error codeCommand set/feature default 15-14 (=01) Word 87 is valid 13 (=1) IDLE IMMEDIATE with UNLOAD FEATURE supported 12-11 (=0) Obsolete 10 (=0) Obsolete 9 (=0) Obsolete 8 (=1) World wide name supported 7 (=0) WRITE DMA QUEUED FUA EXT command supported 6 (=0) WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands supported 5 (=1) General Purpose Logging feature set supported 4 (=0) Obsolete 3 (=0) Obsolete 2 (=0) Media serial number is valid 1 (=1) SMART self-test supported 0 (=1) SMART error logging supported
- 88Error codeUltra DMA Transfer modes 15- 8 (=xx) Current active Ultra DMA transfer mode 15 Reserved (=0) 14 Mode 6 1 = Active 0 = Not Active 13 Mode 5 1 = Active 0 = Not Active 12 Mode 4 1 = Active 0 = Not Active 11 Mode 3 1 = Active 0 = Not Active 10 Mode 2 1 = Active 0 = Not Active 9 Mode 1 1 = Active 0 = Not Active 8 Mode 0 1 = Active 0 = Not Active 7- 0 (=7F) Ultra DMA Transfer mode supported 7 Reserved (=0) 6 Mode 6 1 = Support 5 Mode 5 1 = Support 4 Mode 4 1 = Support 3 Mode 3 1 = Support 2 Mode 2 1 = Support 1 Mode 1 1 = Support 0 Mode 0 1 = Support
- 91Error codeCurrent Advanced power management value
- 92Error codeCurrent Password Revision Code
- C003hError codeOverlay switch failure in Long Sector Access command
- C004hError codeRead Long failure
- C005hError codeWrite Long failure
- C006hError codeWrite Cache enable failure
- up-100Error codeCable is plugged in, and both ends of the link have successfully established communications. Network negotiated at 100 Mbps
- up-1000Error codeCable is plugged in, and both ends of the link have successfully established communications. Network negotiated at 1000 Mbps