Vanderbilt ev alarm paneli All models error codes
Codes
- 0-999Error codeLINE PSTN modem MONITORING Enable this feature to monitor the voltage of the line connected to the modem. GSM Modem Enable this feature to monitor the signal level from the GSM mast connected to the modem. MODE or TIMER MODE - Select a monitoring MODE (DISABLED, ALWAYS ON, FULLSET). The FULLSET option only enables this feature while the system is Fullset. TIMER - Enter the number of seconds for the monitoring TIMER (0-9999 sec). (See System Options on page 255.)
- a24Error codePANIC ALARM Hold-up This zone type is active on a 24-hour basis and activated via a panic button. When a Panic zone is activated it will report a Panic event, independent of panel arming mode. All activation’s are logged and reported if log attribute is active. If the SILENT attribute is set then the alarm will be silent (Activation is reported to ARC), otherwise it will generate a Full alarm
- are24Error codeFIRE Hold-up Fire zones are 24-hour zones for fire monitoring and their response is independent of panel operating mode. When any fire zone opens, a full alarm is generated and the FIRE output type is activated. If the ‘Report only’ attribute is set then activation will only be reported to the central station and a Full Alarm will not be generated
- ery1Error codeX-BUS Indicates the status of the X-BUS communications when in FULL ENGINEER Status programming (Red) Flashes regularly: (once every 1.5 seconds approx) indicates communications status is OK Flashes quickly: (once every 0.25 seconds approx) indicates the keypad is the last expander on the X-BUS If the keypad is being installed for the first time and power is supplied to it before a connection to the controller X-BUS interface is made, the LED remains in the ON state
- F1Error codePanic Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing F1 and F2 soft keys together
- F2Error codeFire Enable to allow fire alarm to be activated by pressing F2 and F3 soft keys together
- F3Error codeMedical Enable to allow medical alarm to be activated by pressing F3 and F4 soft keys together
- hen2Error codeAlarm This output turns on when an alarm has been confirmed. An alarm is confirmed when 2 Confirmed independent zones on the system (or within the same Area) activate within a set time period)
- put3Error codeExternal Bell This output type is used to activate the strobe on the system external bell and is active when Strobe any area strobe is active. By default, this output is assigned to the strobe relay output (Output 3) on the Controller board (NO, COM, NC). Note: An external bell strobe output is automatically activated whenever a zone programmed as an alarm zone triggers an alarm in Fullset or Partset modes. The external bell strobe activates on a ’Fail to Set’ condition if the strobe on the ’Fail to Set’ option is checked in system options
- VPC301Error codeAcil Durum