- 10-2Error code3. ERROR INFORMATION
- A0Error codeThere are 2 or more same address of controller of outdoor unit, indoor unit, FRESH MASTER, or LOSSNAY. Noise has entered into transmission signal and signal was transformed
- A2Error codeError is detected if waveform is transformed when wiring works of transmission wire of outdoor unit, indoor unit, FRESH MASTER or LOSSNAY are done, or polarity is changed with the power on and transmission data collide each other. Defective transmitting receiving circuit of transmission processor Transmission data is changed by the noise on transmission
- A3Error codeTransmission processor could not transmit signal because short cycle voltage of noise and the like have entered into transmission wire continuously. Transmission quantity has increased and transmission is not possible because there was wiring mistake of terminal block for transmission wire (TB3) and terminal block for central control (TB7) in outdoor unit.
- A6Error codeData of transmission processor or unit processor is not transmitted normally because of accidental trouble such as noise or thunder surge. Address forwarding from unit processor is not transmitted normally because of defective transmission processor hardware
- A7Error codeCommon factor that has no relation with abnormality source The unit of former address does not exist as address switch has changed while the unit was energized. Voltage drop and weak signal which lead communication error are caused by over-range transmission wire. • Maximum distance.......200 m • Remote controller line..(12 m) Voltage drop and weak signal which lead communication error are caused by type-unmatched transmission wire. Type...... With shield wire- CVVS, CPEVS With normal wire (no shield)- VCTF, VCTFK, CVV CVS, VVR, VVF, VCT Diameter.....1.25 mm2 or more Voltage drop and weak signal which lead communication error are caused by over-numbered units. Accidental malfunction of abnormality-detected controller (noise, thunder surge) Defective of abnormality- generated controller
- E0Error codeRemote controller transmission error
- E1Error codeRemote controller control board error
- E3Error code2 remote controller are set as “main.” (In the case of 2 remote controllers) Remote controller is connected with 2 indoor units or more. Repetition of refrigerant address Defective transmitting receiving circuit of remote controller Defective transmitting receiving circuit of indoor controller board Noise has entered into transmission wire of remote controller
- E4Error codeRemote controller signal receiving error
- E5Error codeRemote controller transmitting error is detected by indoor unit
- E6Error codeIndoor/outdoor unit communication error
- E7Error codeDefective transmitting receiving circuit of indoor controller board Noise has entered into power supply. Noise has entered into outdoor control wire
- E8Error codeContact failure of indoor/outdoor unit connecting wire Defective communication circuit of outdoor controller circuit board Defective communication circuit of indoor controller board Noise has entered into Indoor/ outdoor unit connecting wire
- E9Error codeIndoor/outdoor unit communication error (Transmitting error) (Outdoor unit)
- EEError codeCombination error between indoor and outdoor units
- F5Error codeDisconnection or contact failure of 63H or TRS connector on outdoor controller circuit board Disconnection or contact failure of 63H or TRS 63H or TRS is working due to defective parts. Defective outdoor controller circuit board
- ge5Error code.4 63 6 c ci i/ /r re ev v Double overcenter safety valve Double overcenter safety valve D pio lou tb inl ge ro av te ior :c e 7n .6te /1r safety valve ing pressure: 5,075 psi piloting ratio: /41 piloting ratio: 4/1 cracking pressure: 5,075 psi Boom functions control P L cracking pressure: 5,075 psi cracking pressure: 5,075 psi hydraulically piloting joistick 2 p, s6 i10 Sin crg ale ko inv ge r pc re en st p se i ulr o rs t eia n f g 5e ,t r 0y a 7tv i 5oa :l pv 4 se / i1 Forks level slave cylinder F XRONT c : 3,190 psi T R LD Y RIGHT Boom lift cylinder Boom telescope cylinder Forks tilt cylinder Anticavitation valve cracking pressure 72 psi 1 2 T P 3 4 ydM raa uin li cv a cl iv rce uitTp 1 test port A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 GPM 34.9 GPM 34.9 GPMM3 P LSC C LSD 5.3 GPM 5.3 GPM 15.8 GPM 15.8 GPM 15.8 GPM 15.8 GPM 15.8 GPM 15.8 GPM 15.8 GPM 15.8 GPM L V 4 p, s3 i50 4 p, s3 i50 6 8 9 T1 XX 3 V3 V7 V5 V9 V11 V13 7 1 4 4,060 psi 2 XX V4 XX V8 XX V6 XX V10 XX V12 XX V14 1 S3 S3.1 S4 S4.1 M1 S5 S5.1capacity: S6 S6.1 0.13USG precharg
- i41Error code1 S3 S3.1 S4 S4.1 M1 S5 S5.1capacity: S6 S6.1 0.13USG precharge P T pressure C1 435 psi X132 A B X119 P C2 Rear axle lockout valve X120 Rear axle lockout cylinder Chassis sway cylinde Air bleeding valve preP su sm urp e s t (et 3a s 2n t 0 d p - pob sry t i) TP 5 H dy od u pr ba illu oel t i ic c na h gl e ly rc a kp t ii ovlo a : t l 4e v /d e 1 X Rear axle steering cylinder
- L1Error codeInput current sensor error L1-phase open error
- MF1Error codeFigure 1 Front panel fixing screws Front panel Front panel fixing screws Front panel fixing screws Photo 2 Photo 3 Fan motor fixing screws Front panel Fan motor Nut Fan motor fixing screws Propeller
- ON1Error codePipe temperature/Liquid (TH3) -60 to 91
- P1Error codeIntake sensor error
- P2Error codePipe (TH2) sensor error
- P4Error codeDrain sensor error/Float switch connector (CN4F) open
- P5Error codeDrain pump error
- P6Error codeFreezing/Overheating protection operation
- P8Error codePipe temperature error
- P9Error codePipe (TH5) sensor error
- S1Error code• Troubles concerning power supply • Bad wiring of the outdoor controller board • The fuses on the outdoor controller circuit board are blown. • Bad wiring of the outdoor controller board • The fuses on the outdoor controller circuit board are blown. • Defective indoor controller board • Miswiring, breaking or poor connection of indoor/outdoor connecting wire • Defective indoor power board
- TB6Error code• Defective remote controller • Breaking or poor contact of the remote controller wire • The remote controller wire short-circuits • Defective indoor controller board
- U1Error codeAbnormal high pressure(63H operated)/High compressor temperature (TRS operated)/Overheating protection operation
- U2Error codeAbnormal high discharging temperature/insufficient refrigerant
- U3Error codeDisconnection or contact failure of connector (TH4, TH33) on the outdoor controller circuit board Defective thermistor Defective outdoor controller circuit board
- U4Error codeDisconnection or contact failure of connectors Outdoor controller circuit (board: TH3, TH6/TH7 ) Outdoor power circuit board: CN3 Defective thermistor Defective outdoor controller circuit board
- U5Error codeAbnormal temperature of heat sink
- U6Error codeCompressor overcurrent interruption/Abnormal of power module
- U7Error codeAbnormality of superheat due to low discharge temperature
- U8Error codeOutdoor unit fan protection stop
- U9Error codeAbnormality such as overvoltage or undervoltage and abnormal synchronous signal to main circuit/Current sensor error
- ZM35-71Error codePFC error (ZM35-71V) (Overvoltage/Undervoltage/Overcurrent)