Teknogen klima santrali All models error codes
Codes
- A0Error code1 There are 2 or more same address of controller of out- door unit, indoor unit, FRESH MASTER, or LOSSNAY. 2 Noise has entered into trans- mission signal and signal was transformed
- A2Error code1 Error is detected if waveform is trans- formed when wiring works of trans- mission wire of outdoor unit, indoor unit, FRESH MASTER or LOSSNAY are done, or polarity is changed with the power on and transmission data collide each other. 2 Defective transmitting receiving circuit of transmission processor 3 Transmission data is changed by the noise on transmission
- A3Error codeError code A3 Error unit IU Unit#1 Time Occurred 2/ 1 4:48 Model name Serial No
- A6Error code1 Data of transmission proces- sor or unit processor is not transmitted normally because of accidental trouble such as noise or lightning surge. 2 Address forwarding from unit processor is not transmitted normally because of defective transmission processor hard- ware
- A7Error codeCommon factor that has no rela- tion with abnormality source. 1 The unit of former address does not exist as address switch has changed while the unit was energized. 2 Voltage drop and weak signal which lead communication error are caused by over-range trans- mission wire. • Maximum distance······ 656 ft [200 m] • Remote controller line.. (39ft [12 m]) 3 Voltage drop and weak signal which lead communication error are caused by type-unmatched transmission wire. Type····· With shield wire- CVVS, CPEVS With normal wire (no shield)- VCTF, VCTFK, CVV CVS, VVR, VVF, VCT Diameter····1.25 mm2 [AWG16] or more 4 Voltage drop and weak signal which lead communication error are caused by over-numbered units. 5 Accidental malfunction of abnormality-detected controller (noise, lightning surge) 6 Defective of abnormality occurred controller
- A8Error code1 Transmitting condition is repeated fault because of noise and the like. 2 Extension of transmission wire voltage and signal is caused by over-range transmission wire. • Maximum distance······ 656 ft [200 m] • Remote controller line····(39 ft [12 m]) 3 Extension of transmission wire voltage and signal is caused by type-unmatched transmission wire. Type····· With shield wire- CVVS, CPEVS With normal wire (no shield)- VCTF, VCTFK, CVV CVS, VVR, VVF, VCT Diameter····1.25 mm2 [AWG16] or more 4 Accidental malfunction of abnormality-occurred controller
- CN2Error codeOutput:230VAC High voltage to IPM&PFC BOARD
- CN3Error codenput:230VAC High voltage
- CN4Error codeOutput: Connection of the high voltage--- (24V BOARD’S CN7) “S”
- CN6Error codeCommunication:Pin1-Pin6 Pulse waveform(0-5VDC),Pin7, Pin9(0VDC),Pin8(0-5VDC),Pin10(5VDC)--to IPM&PFC BOARD
- CN7Error codeOutput: Connection of the high voltage---(MAIN BOARD’S CN7) “S”
- CN8Error codeonnect to DCFAN voltage among phases 0~200VAC
- CN9Error codeInput:Pin2(0-5VDC),Pin3(5VDC),Pin1(0VDC)---PRESSURE SENSOR
- CN10Error codeInput:Pin2 Pin4(0VDC),Pin1 Pin3(0-5VDC)--H/L Pressure switch
- CN11Error codeInput:230VAC High voltage
- CN14Error codeInput:Pin1(5VDC),Pin2(0-5VDC)--COMP. TOP OLP TEMP.SENSOR
- CN17Error codeOutput:230VAC High voltage----REVERSING VALVE
- CN19Error codeOutput:230VAC High voltage----CHASSIS HEATER
- CN20Error codeOutput:230VAC High voltage---COMPRESSOR HEATER
- CN21Error codeOutput:230VAC High voltage---CHASSIS HEATER
- CN24Error codeOutput:230VAC High voltage----CRANKCASE HEATER
- CN29Error codeInput:Pin1,Pin3(0-5VDC),Pin2,Pin4(0VDC)---H/L Pressure Switch
- CN32Error codeConnection to DC FAN
- CN38Error codeOutput:230VAC High voltage----REVERSE VALVE
- E0Error codeError of outdoor EEPROM
- E0-7Error codeCommunication error other than outdoor unit
- E1Error codePower phase sequence error
- E2Error codeCommunication error
- E3Error codeTotal water outlet temperature sensor error (Be valid for main unit)
- E4Error codeUnit outlet water temperature sensor error
- E5Error codePipe temperature sensor error in condenser A
- E6Error codePipe temperature sensor error in condenser B
- E7Error codeOutdoor ambient temperature sensor error
- E8Error codeOutput of the power protector error
- E9Error codeWater flow detection error(Manual recovery)
- EC5CError codeHigh pressure sensor is in open circuit or has short circuited
- EC07Error codeOutdoor fan speed has been out of control
- EC51Error codeOutdoor EEPROM malfunction
- EC52Error codeCondenser coil temperature sensor T3 is in open circuit or has short circuited
- EC53Error codeOutdoor room temperature sensor T4 is in open circuit or has short circuited
- EC54Error codeCompressor discharge temperature sensor TP is in open circuit or has short circuited
- EC57Error codeRefrigerant pipe temperature sensor error
- EC71Error codeOver current failure of outdoor DC fan motor
- EC72Error codeLack phase failure of outdoor DC fan motor
- EC73Error codeZero-speed failure of outdoor DC fan motor
- EL01Error codeIndoor / outdoor units communication error
- EL16Error codeCommunication malfunction between adapter board and outdoor main board
- F3Error codeFan module communica.on error
- F5Error code1 Disconnection or contact failure of 63H connector on outdoor controller circuit board 2 Disconnection or contact failure of 63H 3 63H is working due to defective parts. 4 Defective outdoor controller circuit board
- H0Error codeOutlet water temperature too low