Slant/Fin All models error codes
Codes
- 01Error codeIgnition Failure - 3 unsuccessful ignition
- 02Error codeFlame Failure - 3 losses of flame signal
- 03Error codeWater High Limit Open
- 10Error codeControl Failure
- 11Error codeWater Outlet Sensor Shorted
- 12Error codeWater Inlet Sensor Shorted
- 13Error codeFlue Gas Sensor Shorted
- 19Error codeFlame Detected at Wrong Time
- 20Error codeFlame Detected at Wrong Time
- 21Error codeInternal fault: Flame number of sample mismatch
- 22Error codeFrequency Error
- 24Error codeEarth Connection Faulty
- 25Error codeInternal fault: Spark voltage changed too much during flame sensing time
- 27Error codeInternal fault: Flame rod shorted to ground detected
- 101Error codeExchanger sensor fault
- 110Error codeIgnition failure occurred
- 111Error codeFlame current lower than WEAK threshold
- 115Error codeFan was limited to its minimum duty cycle
- 119Error codeController interaction communications fault
- 129Error codeFan speed failed during pre-ignition
- 131Error codeFan movement detected during standby
- 143Error codeInternal fault: Flame bias out of range 1
- 144Error codeInternal fault: Flame bias out of range 2
- 145Error codeInternal fault: Flame bias out of range 3
- 146Error codeInternal fault: Flame bias out of range 4
- 147Error codeInternal fault: Flame bias out of range 5
- 148Error codeInternal fault: Flame bias out of range 6
- 154Error code
- 155Error code
- 156Error codeCombustion pressure and Flame ON
- 157Error codeCombustion pressure and Flame OFF
- 166Error codeOutlet sensor type was invalid for DHW
- 189Error codeInvalid Flame sensor type setting
- 194Error codeInvalid Ignite failure response setting
- 195Error codeLead Lag backup modulation sensor setting was invalid
- 204Error codeInvalid NTC sensor type setting
- 216Error codeInvalid Run flame failure response setting
- 219Error codeUsing backup Lead Lag header sensor due to sensor failure
- 229Error codeLead Lag slave communication timeout
- 232Error codeInvalid Pressure sensor type setting
- 253Error codeLead Lag modulation sensor not valid with setpoint source
- 255Error codeLead Lag modulation sensor not valid with local modulation source
- 259Error code
- 261Error codeNeighbor burner control blower fault detected
- 272Error codeAbnormal Recycle: Pressure sensor fault
- 274Error codeAbnormal Recycle: Demand off during Pilot Flame Establishing Period
- 278Error codeAbnormal Recycle: LCI off during Pre-Ignition test
- 279Error codeAbnormal Recycle: LCI off during Pre-Ignition time
- 280Error codeAbnormal Recycle: LCI off during Main Flame Establishing Period
- 281Error codeAbnormal Recycle: LCI off during Ignition period