Schneider PowerLogic güç analizörü All models error codes
Codes
- 0-4Error codeSpecifies the percentage of nominal voltage that defines a disturbance.
- 1-3Error codeOver current alarms
- 3-11Error codeLine-to-line voltage harmonics data: Numeric magnitude and angle for the fundamental harmonic, and graphical representation of harmonics for the 3rd to 11th, 13th to 21st, and 23rd to 31st odd harmonics for each line-to-line phase voltage
- 4-30Error code4-30 voltage interruption power quality alarm for phase 2
- 7-15Error codeTotal demand distortion each phase voltage
- 7-501Error codeFunctional earthing; functional grounding (US) * To identify a functional earthing (grounding) terminal, for example, of a specially designed earthing (grounding) system to avoid causing malfunction of the equipment
- 13-21Error codeTotal demand distortion each phase voltage
- 23-31Error codeCrest factor data for each phase current (Ia [I1], Ib [I2], Ic [I3]), line-to-line phase voltage (Vab [U12], Vbc [U23], Vca [U31]), and line-to-neutral phase voltage (Van [V1], Vbn [V2]), Vcn [V3])
- Ch1Error codeAccumulated values on the input metering channels (Ch 1 to Ch 4). • Summary of demand values for input metering channels Ch 1 to Ch 4 in the previous (Last) demand interval. • Demand values for present (Pres) and previous (Last) interval periods, predicted demand (Pred) based on the current consumption rate, and recorded peak demand (Peak) value for the selected input metering channel. • Date and timestamp for the peak demand reading
- EEE519Error codeMaps input metering data, alarms, resets, and reset counts
- EV1Error codeStart of alarm condition
- I1Error codeI1 current harmonics - 10 min
- I2Error codeI2 current harmonics - 10 min
- I3Error codeI3 current harmonics - 10 min
- I4Error codeI4 current transformer's primary winding current rating
- Ph1Error codeCurrent sag alarms for phase 1
- Ph1-3Error codeCurrent swell alarms for phase 1, 2, 3
- Ph3Error codeCurrent sag alarms for phase 3
- PM5561Error code
- PM5570Error codeScreens to set up the alarm / energy pulsing LED, digital inputs/outputs, input metering channels and analog inputs
- PM5660Error codeInstantaneous residual current measurement (I5 and I6)
- PM5760Error codeDiagnostic screens provide meter information for troubleshooting. • Model, serial number, manufacture date, firmware (OS - operating system and RS - reset system) and language versions. OS CRC (cyclic redundancy check) is a number that identifies the uniqueness between different OS firmware versions - this parameter is only available on certain models (e.g., PM5561 / PM5661 / PM5761). • Displays the meter status. • Displays how many times the meter lost control power, and the date and time of its last occurrence. • Displays a graphical representation of the power system the meter is monitoring. • Displays the numeric magnitude and angles of all voltage and current phases
- T1Error codePickup time delay (in seconds)
- T3Error codeMax2
- to200Error code10% of the nominal current, 100% of the nominal voltage and nominal frequency at unity power factor or one (1)
- V1Error codeV1 over total harmonic distortion (THD) voltage alarm
- V1-3Error codeOver total harmonic distortion (THD) voltage alarms
- V2Error codeV2 setpoint alarm
- V3Error codeFrequency setpoint alarm