Codes
- 2-3Error codeUse a higher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchange. Also, try using the cable equalizer if one or more of the following symptoms occurs. Communication error with error codes such as 0-20, 0-23, etc. Modem rate fallback occurs frequently. This setting is not effective in V.34 communications
- 2-13Error codeModem initialization error
- 2-23Error codeJBIG compression or reconstruction error
- 2-24Error codeJBIG ASIC error
- 2-25Error codeJBIG data reconstruction error (BIH error)
- 2-26Error codeJBIG data reconstruction error (Float marker error)
- 2-27Error codeJBIG data reconstruction error (End marker error)
- 2-28Error codeJBIG data reconstruction error (Timeout)
- 2-29Error codeJBIG trailing edge maker error
- 2-50Error codeThe machine resets itself for a fatal FCU system error
- 2-51Error codeThe machine resets itself because of a fatal communication error
- 2-53Error codeSnd msg() in the manual task is an error because the mailbox for the operation task is full
- 4-01Error codeLine current was cut
- 4-5Error codeModem setting for transmission Sets the modem for transmission. The default is "00" (V29). Bit 5: 0, Bit 4: 0 = V29 Bit 5: 0, Bit 4: 1 = V17 Bit 5: 1, Bit 4: 0 = V34* Bit 5: 1, Bit 4: 1 = Not used *V34 is not supported for IP-Fax communication
- 4-7Error codeRestrict TX Retries
- 4-10Error codeCommunication failed because of an ID Code mismatch (Closed Network) or Tel. No./CSI mismatch (Protection against Wrong Connections)
- 5-7Error codeCable equalizer Bit 7: 0, Bit 6: 0, Bit 5: 0 = None Bit 7: 0, Bit 6: 0, Bit 5: 1 = Low Bit 7: 0, Bit 6: 1, Bit 5: 0 = Medium Bit 7: 0, Bit 6: 1, Bit 5: 1 = High Bit 7: 1, Bit 6: 1, Bit 5: 1 = Disabled
- 5-23Error codePrint data error when printing a substitute rx or confidential rx message
- 5-25Error codeSAF file access error
- 6-04Error codeG3 ECM - RTC not detected
- 6-05Error codeG3 ECM - facsimile data frame not received within 18 s of CFR, but there was no line fail
- 6-06Error codeG3 ECM - coding/decoding error
- 6-08Error codeG3 ECM - PIP/PIN received in reply to PPS.NULL
- 6-10Error codeG3 ECM - error frames still
- 6-21Error codeV.21 flag detected during high speed modem communication
- 6-22Error codeThe machine resets the sequence because of an abnormal handshake in the V.34 control channel
- 15-43Error codeAddress Format Error
- 15-61Error codeAttachment File Format Error
- 15-62Error codeTIFF File Compatibility Error
- 15-63Error codeTIFF Parameter Error
- 15-64Error codeTIFF Decompression Error
- 15-73Error codeMDN Status Error
- 15-74Error codeMDN Message ID Error
- 15-80Error codeMail Job Task Read Error
- 15-81Error codeRepeated Destination Registration Error
- 15-91Error codeSend Registration Error
- 15-93Error codeMemory Access Error
- 22-05Error codeNo G3 parameter confirmation answer
- 25-00Error codeThe machine software resets itself after a fatal transmission error occurred
- 31-21Error codeLAN Fax Error
- B804Error codeWhen the actuator on the tray activates the upper tray full sensor [H] the tray lift motor [A] switches off. Operation resumes after some copies are removed from the tray. Upper Tray Capacity: 2,000 sheets (A4, LT)
- B805Error codeThe operation of the upper tray full sensor is the same as the B804. Capacity: 1,500 sheets for A3, B4 or other large paper. An additional upper tray full sensor (below sensor [H]) allows more sheets to stack on the upper tray. Capacity: 3,000 sheets (A4, LT)
- F0Error codeV.34 modem error
- F6Error codeSG3 modem error
- M1Error codeFinisher Entrance Motor
- M10Error codeStacking Sponge Roller Motor
- M11Error codeFold Plate Motor
- M12Error codeFold Roller Motor
- M13Error codeCorner Stapler Rotation Motor
- M14Error codePositioning Roller Motor