ResMed hasta monitörü All models error codes
Codes
- 001Error codeThe AirSense 10 runs a controlled speed ramp when therapy starts. If the blower motor doesn't hit its minimum operating RPM within that startup window, the device logs Error 001 and kills therapy. It's different from Error 12, which fails mid-session. This one's specifically a startup problem, usually fixable without touching any internal hardware.high
- 1Error code1 Yanıp Sönme (LED)
- 2Error code2 Yanıp Sönme (LED)
- 3Error codeOrta
- 006Error codeError 006 on the ResMed AirSense 10 is a therapy alert that fires when the device's leak detection algorithm catches a sustained leak it can't compensate for on its own. Unlike the hardware E-codes like Error 12, this doesn't mean something broke inside. It's the machine saying the pressure isn't getting where it needs to go because air's escaping somewhere in the mask interface.moderate
- 12Error codeError 12 on the ResMed AirSense 10 and AirSense 11 means the blower motor has failed, stalled, or is drawing abnormal current. The AirSense 10 uses a brushless DC blower motor that is sealed inside the device chassis and is not user-accessible or user-replaceable. When Error 12 appears the device cannot deliver pressurized air, and therapy stops immediately.critical
- 13Error codeError 13 on the ResMed AirSense 10 means the device's pressure relief system got triggered by an abnormally high pressure event. Either the motor tried to drive pressure beyond the safe range, or the pressure sensor caught an anomaly that forced the relief valve to activate. It's a pressure regulation problem inside the device, not a mask or leak issue.high
- 21Error codeError 21 means the AirSense 10 detected a sustained leak that blew past what it could compensate for. ResMed defines a large leak as more than 24 L/min above the mask's normal vent flow. Once that threshold is crossed and stays there, the machine can't hold your prescribed pressure and logs the error.moderate
- 24Error codeWhen Error 24 fires, your AirSense 10's climate control subsystem detected an out-of-range temperature reading or a complete loss of signal from the heating element. Basically the sensor that's supposed to confirm the humidifier or ClimateLine tube is heating correctly can't verify that, so the machine shuts the whole heating circuit down to protect itself.moderate
- E01Error codeE01 / 1 Bip Sesi
- E02Error codeE02 / 2 Bip Sesi
- E03Error codeE03 / 3 Bip Sesi
- E04Error codeE04 / Kesintisiz Bip
- nic06Error codeHOS Panic 06 on the ResMed AirSense 10 is a hardware operating system panic, basically a firmware-level crash where the device's embedded OS hit a fatal error it couldn't recover from on its own. The unit locks up and shows the code until you power-cycle it. It's a software fault, not a hardware component failure, and it resolves with a reset the vast majority of the time.high