ResMed All models error codes
Codes
- 001Error codeThe AirSense 10 runs a controlled speed ramp when therapy starts. If the blower motor doesn't hit its minimum operating RPM within that startup window, the device logs Error 001 and kills therapy. It's different from Error 12, which fails mid-session. This one's specifically a startup problem, usually fixable without touching any internal hardware.highbeginner
- 006Error codeError 006 on the ResMed AirSense 10 is a therapy alert that fires when the device's leak detection algorithm catches a sustained leak it can't compensate for on its own. Unlike the hardware E-codes like Error 12, this doesn't mean something broke inside. It's the machine saying the pressure isn't getting where it needs to go because air's escaping somewhere in the mask interface.moderatebeginner
- 010Error codeError 010 / 011 / 012
- 12Error codeError 12 on the ResMed AirSense 10 and AirSense 11 means the blower motor has failed, stalled, or is drawing abnormal current. The AirSense 10 uses a brushless DC blower motor that is sealed inside the device chassis and is not user-accessible or user-replaceable. When Error 12 appears the device cannot deliver pressurized air, and therapy stops immediately.criticalbeginner
- 013Error codeError 013
- 13Error codeError 13 on the ResMed AirSense 10 means the device's pressure relief system got triggered by an abnormally high pressure event. Either the motor tried to drive pressure beyond the safe range, or the pressure sensor caught an anomaly that forced the relief valve to activate. It's a pressure regulation problem inside the device, not a mask or leak issue.highbeginner
- 017Error codeError 017 / 018
- 21Error codeError 21 means the AirSense 10 detected a sustained leak that blew past what it could compensate for. ResMed defines a large leak as more than 24 L/min above the mask's normal vent flow. Once that threshold is crossed and stays there, the machine can't hold your prescribed pressure and logs the error.moderatebeginner
- 24Error codeWhen Error 24 fires, your AirSense 10's climate control subsystem detected an out-of-range temperature reading or a complete loss of signal from the heating element. Basically the sensor that's supposed to confirm the humidifier or ClimateLine tube is heating correctly can't verify that, so the machine shuts the whole heating circuit down to protect itself.moderatebeginner
- 206Error codeGeneral hardware failure
- E-87Error codeMotor failed to start, or motor hardware fault
- E-100Error codeInternal system error
- E-103Error codeMotor overheating
- E01Error codeMotor fault/motor failed to start
- E02Error codePressure sensor fault
- E03Error codeFlow sensor fault
- E04Error codePower supply fault
- E05Error codeTemperature / overheating fault
- E06Error codeHumidifier fault
- E07Error codeCommunication error between motor and controller
- F001Error codeSystem/algorithm controller fault
- F003Error codeFlow sensor calibration failure
- F005Error codePressure transducer fault
- F006Error codeData acquisition fault
- F010Error codeBlower/motor fault - most common F-code
- F011Error codeMotor overheating
- nic06Error codeHOS Panic 06 on the ResMed AirSense 10 is a hardware operating system panic, basically a firmware-level crash where the device's embedded OS hit a fatal error it couldn't recover from on its own. The unit locks up and shows the code until you power-cycle it. It's a software fault, not a hardware component failure, and it resolves with a reset the vast majority of the time.highbeginner
- ror001Error codeError 001
- ror1Error codeBlower motor faults or stalling
- ror3Error codePressure sensor calibration failure
- ror004Error codeInternal software, blower, or pressure sensor faults
- ror4Error codeUndefined software or circuit error
- ror006Error codeError 006 / 007 / 008
- ror008Error codeHumidifier or heating plate issue
- ror9Error codeMainboard or control failure
- ror010Error codeError 010 / 011 / 012
- ror013Error codeError 013
- ror14Error codeSoftware or PCB failure (data/logic layer)
- ror017Error codeError 017 / 018
- ror21Error codeSevere hardware or calibration fault
- ror303Error codeOxygen added during Learn Circuit
- ror409Error codeLeak or misassembled circuit
- ror420Error codeCircuit flow resistance out of range