Phoenix radyant ısıtıcı All models error codes
Codes
- art13Error codePerforming any work in the plumbing system without either powering off the water heater or isolating the water heater through the use of shut-off valves could result in a condition referred to as “dry-firing”. Dry-firing the water heater will damage the heat exchanger, and could result in property damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty. • To avoid severe burns, allow the heater to cool before performing maintenance. The owner should make necessary arrangements with a qualified heating contractor for periodic maintenance of the heater The installer must also inform the owner that lack of proper care and maintenance may result in a hazardous condition, premature heater
- d1Error codeActual temperature from upper tank sensor
- d2Error codeActual temperature from lower tank sensor
- d5Error codeOutdoor Sensor
- d6Error codeActual Fan Speed divided by 10 (Example: If fan speed displayed is 410 x 10 = 4100 RPM actual fan speed)
- d7Error codeActual Ionization Current read from flame rectification probe
- d10Error codeActual status of bus communication - co = connected, nc = not connected
- F00Error codeHigh temperature switch limit exceeded 194oF
- F01Error codeVent temperature limit exceeded
- F02Error codeInterrupted or shorted upper temperature sensor
- F03Error codeInterrupted or shorted lower temperature sensor
- F05Error codeUpper temp. sensor exceeds 194oF
- F06Error codesensor exceeds 194oF
- F09Error codeNo flame detected - Heater will make three attempts at ignition before the control goes into this lockout condition. Will reset in 1 hour
- F10Error codeLoss of flame signal - The heater will attempt to relight four times before the control goes into this condition. Will reset in 1 hour
- F11Error code
- Is24Error code
- L3Error codeMotor Connection
- LP-179Error codePHOENIX WITH STORAGE TANK HOT OUT COLD IN GAS SHUT-OFF BACKFLOW BALL VALVE PREVENTER EXPANSION TANK HOT WATER OUTLET T&P RELIEF VALVE LATOR ote 4) ASTAT TROL SPRING CHECK DRAIN VALVE VALVE LP-179-O COLD WATER INLET 08/16/22