Olimpia Splendid All models error codes
Codes
- a27Error codeTECHNICAL DATA Rated conditions In cooling and dehumidifying mode: Air entering the inside unit at 27°C b.s. and 19°C b.u. with air entering the outside unit at 35°C b.s. In heating mode: Air entering the inside unit at 20°C b.s. with air entering the outside unit at 7°C b.s. and 6°C b.u. Preliminary instructions The maximum length allowed for pipes is 1 m. The pipes must be smooth on the inside, and with a diameter of 162 mm. Pipes cannot be curved or bent. It is necessary to use the grilles provided, or grilles which keep the same features. The machine capacity with heat pump is measured with outside temperatures of 7°C. The capacity decreases as the outside temperature decreases. Proper use The air-conditioner should be used for the exclusive purpose of producing hot or cool air (on demand) for the sole purpose of obtaining a comfortable temperature in the room. Improper use of the machine (outside and inside units) causing damage to persons, property or animals relieve OLIMPIA SPLENDID of any liability
- ast162Error codePour exécuter le perçage, procéder de la façon suivante: Placez le gabarit du perçage fourni contre le mur en respectant les distances minimums: par rapport au plafond, au sol et aux murs latéraux, indiqués sur ce gabarit. Celui-ci peut être maintenu dans la bonne position avec du ruban adhésif. A l'aide d'une petite perceuse ou d'un pointeur, tracez avec grand soin les centres des différents trous à effectuer avant leur réalisation. Effectuez avec un foret scie-trépan d'un diamètre minimum égal à 162 mm, les deux trous pour l'entrée et la sortie de l'air. Avertissement: Ces trous doivent être exécutés avec une légère inclinaison vers l'extérieur pour empêcher d'éventuelles rentrées d'eau par les conduits (voir fig. 6) La plus grande partie de la matière enlevée est expulsée vers l’extérieur; il faut donc veiller à ce qu’en tombant, elle n’aille pas heurter les personnes ou les objets se trouvant dessous. Pour éviter le plus possible la rupture de l'enduit extérieur, il faut procéder avec beaucoup de soin pour l'exécution de la partie finale du trou en diminuant un peu la pression exercée sur la perceuse à scie-trépan. Exécuter les trous relatifs à l'encrage de la bride au mur en u
- BIG20Error codeESQUEMAS ELÉCTRICOS BIG 20 Interna (fig. 52) A Grupo do motor B Transformador C Fusível D Head ezchanger - Permutador de calor E Visor F Termóstato (temperatura ambiente) G Termístor (temperatura do tubo) H Motor da ranhura I Motor da ranhura L Unidade de comando M Condensador do ventilador N Motor do Ventilador P Unidade interna W1 Secç.-n°pólos (2,5 mm2-5)- H05VV-F W2 Secç.-n°pólos (1 mm2-2)- H05VV-F W3 Secç.-n°pólos (2,5 mm2-3)- H05VV-F Externa (fig. 53) A Motor do compressor B Placa de junções C Condensador D Protecção do motor (interna ou externa) E Condensador do ventilador F Bobina da válvula H Motor do Ventilador I Unidade externa W1 Secç.-n°pólos (2,5 mm2-5)- H05VV-F W2 Secç.-n°pólos (1 mm2-2)- H05VV-F SS Sensor de descongelamento
- BIG25Error codeESQUEMAS ELÉCTRICOS BIG 25 Interna (fig. 54) A Grupo do motor B Transformador C Fusível D Permutador de calor E Visor F Termóstato (temperatura ambiente) G Termístor (temperatura do tubo) H Motor da ranhura I Motor da ranhura L Unidade de comando M Condensador do ventilador N Motor do Ventilador P Unidade interna W1 Secç.-n°pólos (2,5 mm2-5)- H05VV-F W2 Secç.-n°pólos (1 mm2-2)- H05VV-F Externa (fig. 55) A Condensador B Condensador do ventilador C Motor do compressor (Termóstato interno) D Opcional E Motor do Ventilador (Termóstato interno) F Relé CA G Válvula H Potência secç. -n°pólos (2,5 mm2 - 3) - H05VV-F W1 Secç.-n°pólos (2,5 mm2-5)- H05VV-F W2 Secç.-n°pólos (1 mm2-2)- H05VV-F TH3 Sensor de descongelamento
- di2Error codeINSTRUCTIONS FOR INSTALLATION To obtain the best results and optimum performance, follow the instructions for correct installation provided in this manual. Failure to follow the instructions and apply the rules indicated may cause malfunction of the appliance and relieves the manufacturer, OLIMPIA SPLENDID of any form of guarantee and liability for damages to persons, animals or property. The electrical system must comply with the regulations and rating data in the technical sheet, with good grounding. - - No obstructions shall be present which may hinder proper air circulation either on t
- di15Error code- The unit should not be installed in a position where it interferes with the passage of persons or animals. - The unit should not be installed downwind of chimneys discharging burnt gas or subject to emissions of fumes, oily or corrosive gasses. Also, the maximum difference in height between the two units should not exceed 5 m (fig. 17)
- di40Error codeif after that period the setting of 50 Pa is not reached, it means there is a high level of moisture in the circuit or that there is a leak. Keep the vacuum pump in operation for another 3 hours. After that time, if the value has still not been reached, it will be necessary to find the leak. 26 ref. A).
- di45Error codeInstallation of air pipes and external gratings After drilling the holes, the plastic pipes supplied with the air conditioner have to be fitted through them. The pipe with insulation on the inside has to be fitted in the right-hand hole with the insulated part toward the inside as indicated on the label applied to it. The length of the pipes should be 45 mm less than that of the wall. To cut the pipe, a normal handsaw can be used. After cutting the pipes, fit the ends into the two internal anchoring flanges (fig. 11). The tube diameter is nearly the same as those carried out using the 162 mm nominal diameter core drill. In order to introduce the tubes, they must therefore be forced slightly using, in the most difficult cases, a normal rubber hammer (fig. 12). Having the hole internal diameter extremely similar to the tube external diameter avoids dangerous slacks which may generate humidity infiltrations or air noises. Should the insertion prove to be too difficult, we suggest you drill using the core bit inside the hole so as to widen the internal diameter slightly. Next, fit the pipes into the holes in the wall and fasten the flanges with 4 anchor bolts with diameter 6, taking ca
- eno10Error codeWORKING TESTS AND IDENTIFICATION OF POSSIBLE MALFUNCTIONS The program introduced in the microprocessor of this device makes it possible to run a brief self-test to ensure that the machine functions normally by starting each of its internal components. Carry out this operation at the end of the installation. - At the beginning and end of the self-test procedure the status of configuration of the machine will be displayed for a few seconds as follows: A red led (filter): off = UNICO on = UNICO HP (with heat pump) B green led (compr.): off = with correction of room temperature on = without correction of room temperature C orange led (timer): off = without correction of room temperature on = with correction of room temperature D green led (power): off = stand-by in case of black-out on = restart in case of black-out
- gge10Error codeChoice of best positi installing the air cond The air conditioner must be i on a wall that communicates outside. Caution: After determining t place for installation as de above, check to make sure wall can be drilled in tha without interfering with structures or installations ( piers, pipes, wires, etc.). Check again to make sure t no obstacles to air circ through the holes to be drille plants and their leaves, s panelling, blinds, gratings too dense, etc.). Dimensions and featu site where air conditio installed Before installing the air con it is essential to make an a calculation of the heat summer (and cold load in w models with heating pump site of installation. The more accurate this cal is made the better the air con will be able to do its job. To make these calculation directly to the regulations i (UNI ref. Law 10/91) or to the both printed and computerize on those regulations. For particularly sign applications, we reco contacting expert heating en
- i6Error codeion can be performed enclosed in the wall, in dicated in the template. t is necessary to: e 6 caps on the front 19 ref. A) he six fixing screws of fig. 19 ref. B) e front cover (fig. 19 ref. e cover of the electrical 9 ref. D) he cable clamp (fig. 20 he cable fixing screws inal board (fig. 20 ref. oden wedge on the back (fig. 20 ref. C) cable ew cable following the e wooden wedge from unit hree poles of the cable inal board and tighten able with the clamp (fig. rotection of the board . D) he front cover of the ith the six screws oles with the six caps . A) : these s should be d with the already on the bracket. e instructions before ly the electric n
- of18Error codePrécautions pour le montage Zones avec probable accumulation de neige. Positionner l’unité extérieure sur un plan surélevé (muret) à une hauteur supérieure au niveau maximal de chute de neige prévisible (fig. 18), étant donné que: - si l’appareil n’est pas à pompe de chaleur, lors de la fonte de la neige l’eau pourrait s’infiltrer à l’intérieur de l’unité et provoquer des dommages aux composants électriques. - si l’appareil est à pompe de chaleur, l’accumulation de neige empêche la circulation normale de l’air et rend le drainage du condensat plus difficile. Positionnement de l’unité sur un lieu de passage (terrasse, terrain, toit, etc.) dans une zone d’accès dif- ficile. La base d’appui doit avoir des caractéristiques de bon drainage des eaux et doit éviter l’accumulation possible, sous l’unité, de saleté (ex. feuilles sèches fig. 19). Dans ce cas réaliser un plan surélevé de 10-15 cm où fixer l’unité à l’aide de prisonniers pour fondation. Aucune intervention n’est demandée en cas de positionnement sur des balcons, étant donné qu’ils sont déjà pourvus d’une pente suffisante pour l’écoulement régulier de l’eau et sont suffisamment à l’abri de l’accumulation de saleté. Sur châssis
- T9Error codeContrôle de la direction du soufflage d’air Le soufflage d’air peut être contrôlé aussi bien dans le sens horizontal que vertical. Le contrôle de la direction horizontale ne peut être effectué avec la télécommande, mais seulement manuellement en agissant sur les lamelles pour la déviation en sens horizontal du flux qui se trouve à l’intérieur de la bouche de sortie. IMPORTANT: le contrôle de la direction horizontale doit être effectué seulement lorsque les deux déflecteurs mobiles sont à l'arrêt. Pour contrôler la direction verticale du soufflage d’air, il y a deux possibilités: - oscillation continue du flux d'air peut être obtenue en appuyant sur le bouton T9 Activation/ Désactivation des déflecteurs mobiles. Ainsi les ailettes de la grille effectuent une oscillation complète. - bloquer les déflecteurs mobiles dans la position qui sied le plus, en appuyant une autre fois sur le bouton T9 pendant que les ailettes bougent. En appuyant une autre fois le bouton T9, le mouvement automatique des déflecteurs mobiles se remet en marche. IMPORTANT : Le mouvement des déflecteurs mobiles ne doit jamais être forcé manuellement. Contrôle de la vitesse du ventilateur Le contrôle de la vitesse