Nokia switch All models error codes
Codes
- 1Error codeSP-%c disk controller failure
- 11Error codeSP-%c 100baseT internal fault on SP to SP interface
- 102Error codeSP-%c lost communication with %s
- 103Error codeSP-%c %s Failure - %s
- 104Error codeIndicates a software process on the SP is not responding. Software fault on the indicated SP or hardware fault on the front SP module
- 105Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem error
- 106Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem error
- 107Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem
- 108Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem error
- 109Error codeIndicates communications between SPs has failed on either the Ethernet or ATM fabric. Software fault on the indicated SP, hardware fault on the front SP module, Enet chip on SP rear module has faulted or ATM interface on the SF has faulted
- 110Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem error
- 111Error codeIndicates a software error. Corrupted disk file system or software or CPU subsystem error
- 1001Error codePossible cabling fault, provisioning error or faulted IOM
- 1008Error codeCorrupted disk file system or software or CPU subsystem error or module fault
- 1010Error codeCALEA-CDC failed for caseId %s - socket failure
- 1014Error codeCALEA-CDC failed for caseId %s - internal failure
- 1015Error codeCALEA-CCC %s failed for caseId %s - routing failure
- 1016Error codeCALEA-CCC %s failed for caseId %s - resource failure
- 1018Error codeCALEA-CCC failed for caseId %s - switching resource failure
- 1021Error codeCALEA-CCC %s failed for caseId %s - remote failure
- 1022Error codeCALEA-CCC failed for caseId %s - internal failure
- 1026Error codeFacilities faults or provisioning
- 1028Error codeFacilities faults or provisioning
- 1030Error codeFacilities faults or provisioning
- 1032Error codeFacilities faults or provisioning
- 1035Error codeFacilities faults or provisioning
- 1037Error codeFacilities faults or provisioning
- 1055Error codeThis alarm is obsolete
- 1060Error codeIndicates the E1 input (A or B) on the Timing Module cannot detect a signal. Cabling or faulted SP TMG
- 1064Error codeTMG-%c - Alarm Indication Signal on BITS Input %c
- 1065Error codeTMG-%c - Alarm Indication Signal on BITS Input %c cleared
- 1085Error codeIOM-%d TSU %s Error -%s
- 1086Error codeSP-%c - EMS connectivity failure - IP-%s
- 1090Error codeIOM-%d APC-%d Receiving Switch Fabric Parity Errors from both SFs
- 1091Error codeIOM-%d APC-%d Receiving Switch Fabric Parity Errors from SF-%c
- 1094Error codeSPs lost communication
- 1095Error codeSP-%c lost communication with SP-%c
- 1096Error codeSPs lost communication
- 1097Error codeSPs lost communication
- 1107Error codePossible cabling fault, provisioning error or faulted IOM
- 1108Error codeOperator initiated backup failure
- 1109Error codeScheduled backup failure
- 1110Error code%s - Remote Failure Indication (Line)
- 1111Error code%s - Remote Failure Indication (Line) cleared
- 1112Error code%s - Alarm Indication Signal (Line)
- 1113Error code%s - Alarm Indication Signal (Line) cleared
- 1114Error code%s - Remote Failure Indication Server (Path)
- 1115Error code%s - Remote Failure Indication Server (Path) cleared
- 1116Error code%s - Remote Failure Indication Connectivity (Path)
- 1117Error code%s - Remote Failure Indication Connectivity (Path) cleared