Konecranes vinç kontrol sistemi All models error codes
Codes
- A24Error codeThe values in the Fault history, MWh-counters or operating day/hour counters might have been changed during the previous mains interrupt
- A29Error codeExpansion board thermistor input has detected motor overtemperature
- A30Error codeMotor phase currents unbalanced (only in models 110F-800F, 90K-630K)
- A45Error codeHeat sink overtemperature warning, temperature more than +70°C (158°F)
- b1Error codeReverse
- E101Error codeFan PUDC24Z4 80mm, 24VDC
- E102Error codeFan MC24B3 120mm, 24VDC
- E103Error codeFan Major JG 24 B3 150mm, 24VDC
- E104Error codeFan D2E133-AM47 220VAC
- E105Error codeFan W2G076-BC31-12 80mm, 24VDC
- E109Error codeFan D2E146-CD51-09 220VAC
- E110Error codeFan D2E133-DM47 230VAC
- E821Error codeCurrent Sensor LEM 205-S 200A
- E822Error codeCurrent Sensor LEM 305-S 300A
- E823Error codeCurrent Sensor LEM 305-S/SP1 300A
- F1Error codeOvercurrent
- F2Error codeOvervoltage
- F3Error codeEarth fault
- F4Error codeInverter fault
- F5Error codeCharging switch
- F9Error codeUndervoltage
- F10Error codeInput line supervision
- F11Error codeOutput phase supervision
- F13Error codeInverter undertemperature
- F14Error codeInverter overtemperature
- F18Error codeAnalog input hardware fault
- F20Error code10V reference
- F21Error code24V supply
- F22Error codeEEPROM checksum fault
- F25Error codeMicroprocessor watchdog-fault
- F26Error codePanel communication error
- F27Error codeProfibus communication error
- F29Error codeThermistor fault
- F32Error codeEncoder direction fault
- F33Error codeI2t and current cutter supervision
- F34Error codeGenerator side current limit
- F36Error codeReference value fault
- F53Error codeNo brake
- F54Error codeProfibus control fault
- n1Error codeOutput frequency to the motor
- n2Error codeCalculated motor speed with open loop and measured motor speed with closed loop (encoder)
- n3Error codeMeasured motor current
- n6Error codeCalculated motor voltage
- n7Error codeMeasured DC-bus voltage (DC-link = DC-bus)
- n8Error codeTemperature of heat sink
- n25Error code100% = motor temperature increased up to nominal
- n28Error codeCalculates the number of motor revolutions after slowdown limit. Operates within slowdown limit area. Not operating, if parameter P5.2 setting value is “0”