JCB Fastrac traktör All models error codes
Codes
- A2194Error codeInternal checksum failure
- A2195Error codeEEPROM compatibility failure
- A2196Error codeEEPROM checksum error
- A2197Error codeInvalid fault code in the DTC container Overwitten secured variable
- A2203Error codeFront Left Wheel (S-E) Open circuit or Shorted to Battery
- A2204Error codeRear Right Wheel (S-D) Open circuit or Shorted to Battery
- A2205Error codeRear Left Wheel (S-C) Open circuit or Shorted to Battery
- A2207Error codeFront Right Wheel (S-F) Open circuit or Shorted to Battery
- A2228Error codeRear Left Wheel (S-C) sensor airgap
- A2229Error codeRear Right Wheel (S-D) sensor airgap
- A2230Error codeFront Left Wheel (S-E) sensor airgap
- A2231Error codeFront Right Wheel (S-F) sensor airgap
- A2234Error codeRear Left Wheel (S-C) sensor airgap (no signal)
- A2235Error codeRear Right Wheel (S-D) sensor airgap (no signal)
- A2236Error codeFront Left Wheel (S-E) sensor airgap (no signal)
- A2237Error codeFront Right Wheel (S-F) sensor airgap (no signal)
- A2240Error codeRear Left Wheel (S-C) damaged sensor ring
- A2241Error codeRear Right Wheel (S-D) damaged sensor ring
- CR2Error codeHand Throttle Sensor Supply Splice
- H1Error codeLow pressure warning light switch
- H2Error codeLow pressure warning light switch
- H3Error codeLow pressure warning light switch
- H4Error codeLow pressure warning light switch - parking brake
- K4103Error codeSolenoid valve 1, Current above normal: Short circuit between cables
- K4104Error codeSolenoid valve 1, Calibration value missing
- K4107Error codeSolenoid valve 2, Short circuit
- K4108Error codeSolenoid valve 2, Current above normal: Short circuit between cables
- K4109Error codeSolenoid valve 2, Calibration value missing
- K4112Error codeSolenoid valve 3, Short circuit
- K4113Error codeSolenoid valve 3, Current above normal: Short circuit between cables
- K4114Error codeSolenoid valve 3, Calibration value missing
- K4117Error codeSolenoid valve 4, Short circuit
- K4118Error codeSolenoid valve 4, Current above normal: Short circuit between cables
- K4119Error codeSolenoid valve 4, Calibration value missing
- K4121Error codeSolenoid valve 5, Current above normal: Short circuit between cables
- K4122Error codeSolenoid valve 5, Short circuit
- K4123Error codeSolenoid valve 5, Calibration value missing
- K4125Error codeSolenoid valve 6, Current above normal: Short circuit between cables
- K4127Error codeSolenoid valve 6, Short circuit
- K4128Error codeSolenoid valve 6, Calibration value missing
- K4132Error codeCam speed sensor signal missing
- K4140Error codeMPROP control, High side short circuit to HIGH SOURCE
- K4141Error codeMPROP control, Low side short circuit to GROUND
- K4142Error codeMPROP control, Low side short circuit to HIGH SOURCE
- K4143Error codeMPROP control, High side short circuit to GROUND
- K4144Error codeMPROP control, Open circuit
- K4150Error codeECU Internal fault 0101 - MPROP control, Metering unit AD-channel voltage above normal
- K4151Error codeECU Internal fault 0102 - MPROP control, Metering unit AD-channel voltage below normal
- K4152Error codeMPROP control, Powerstage over temperature
- K4155Error codeECU temperature sensor voltage above normal or open circuit