Immergas All models error codes
Codes
- E27Error codeSirkülasyon pompası
- E31Error codeUzaktan Kontrol Cihazı Uyum Sağlayamıyor
- P0Error codeEstablishes the switch-off method in DHW mode. 1 Correlated: the boiler switches off on the basis of the temperature set.
- P2Error codeTeh pump can function in two ways. 0 intermittent: In winter "mode" the pump is managed by the room thermostat or by the remote control 1 continuous: In "winter" mode the pump is always powered and so functions continu ously
- P3Error codeTeh boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 = Main zone control 2 =General alarm 3 = CH phase active 4 = External gas valve power supply 5 = (Do not use on this boiler model)
- P4Error codeTeh boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 =General alarm 2 = CH phase active 3 = External gas valve power supply 4 = Secondary zone control (from TA on relay board contact 5 = Heat pump
- P5Error codeTeh boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 = Chiller remote activation 2 =General alarm 3 = CH phase active 4 = External gas valve power supply 5 = heat pump 6 = activation of storage tank pump
- S0Error codeTeh boiler also has electronic modulation that adapts the boiler potentiality to the ef fective heating demand of the house. Tehrefore the boiler works normally in a variable gas pressure field between minimum and maximum power depending on the system heat load, setting fan speed (in rpm, hundreds of revs are represented on the display). N.B.:the boiler is produced and calibrated in the central heating phase at nominal output. Approximately 10 minutes are needed to reach the nominal heat output, which can be changed using the parameter (S3). N.B.: selection of parameters in the presence of requests, allows boiler functioning with current equal to the respective value
- S1Error codeDefines the operating speed of the fan at maximum DHW output
- S2Error codeDefines the operating speed of the fan during the ignition phase
- S5Error codeDefines the minimum flow temperature
- S6Error codeDefines the maximum flow temperature
- t0Error codeDefines the minimum flow temperature
- t1Error codeDefines the maximum flow temperature
- t2Error codeTeh boiler is set to switch-on immediately afetr a request. In the case of particular systems (e.g. area systems with motorised thermostatic valves etc.) it could be necessary to delay switch-on (with 10 step)
- t4Error codeEstablishes what the indicator displays 14 (Fig. 2-1).
- t6Error codeThe boiler is set to switch-on immediately after a request. In the event of particular systems (e.g. area systems with motorised thermostatic valves etc.) it may be necessary to delay ignition
- t8Error codeEstablishes what the indicator displays 19 (Fig. 37). “Summer” mode: 0: the indicator is always off. 1: pump active displays the flow temperature, pump off the indicator is off.
- t9Error codeIncreases the flow off temperature at ignition only in the first 60 seconds. After the flame is detected, the temperature is increased by t9
- U50Error codeLafunzione ha una durata di 18 ore ed è possibile interromperla mediante la pressione del pulsante “ESC” ed impostando la funzione su “OFF” L’atti vazione della funzione viene segnalata dal conto alla rovescia visualizzato sull’indicatore (14)