Hyundai akülü matkap All models error codes
Codes
- A01Error codeFour options: select codes: 0.... Keypad potentiometer 1.... Control terminal input 2.... Standard operator 3.... Remote operator(communication)
- A27Error codeJogging stop operation selection
- A29Error codeManual torque boost setting
- A31Error codeV/F characteristic curve selection
- A32Error codeV/F gain setting
- A35Error codeDC braking output delay time setting
- A40Error codeJump(center) frequency setting
- A51Error codeFeed-back method setting
- A52Error codeAutomatic (output) voltage regulation, selects from three type of AVR functions three option codes: 0... Constant ON 1... Constant OFF 2... OFF during deceleration
- A55Error codeDuration of 2nd segment of deceleration, motor range is 0.1 to 3000 sec. Second acceleration can be set by the [2CH] terminal input or frequency transition setting
- AL0Error codeWhen an alarm occurs AL0 AL1 AL2
- b01Error codeSelect inverter restart method, four option codes: 0.... Alarm output after trip, no automatic restart 1.... Resume operation after frequency matching 3.... Resume previous freq. after freq. matching, then decelerate to stop and display trip info. • Over current and over voltage trip restart up to 3 times, under voltage trip restart up to 10time
- b02Error codeThe amount of time a power input under voltage can occur without tripping the power failure alarm. Range is 0.3 to 1.0sec. If under-voltage exists longer than this time, the inverter trips, even if the restart mode is selected
- b03Error codeTime delay after under-voltage condition goes away, before the inverter runs motor again. Range is 0.3 to 10.0 seconds. Input Failure power Motor speed b02 b03
- b04ParameterSet a level between 20% and 120% for the rated inverter current. setting range- 0.2 × (inverter rated current)∼ 1.2 × (inverter rated current)
- b05Error codeSelect from two curves, option codes: 0....(SUB) reduced torque characteristic 1....(CRT) constant torque characteristic Constant torque(CRT) 100 Output 80 Reduced torque(SUB) current 60 in [%] 0 5 20 60 120 Output frequency (Hz)
- b06Error codeSelect overload or overvoltage restriction modes 0.... Overload, overvoltage restriction mode OFF 1.... Only overload restriction mode ON 2.... Only overvoltage restriction mode ON 3.... Overload overvoltage restriction mode ON
- b07ParameterSets the level for overload restriction, between 20% and 200% of the rated current of the inverter, setting range 0.2x(inverter rated current) ~ 2.0x(inverter rated current)
- b12Error codeSelect the type of initialization to occur, two option codes: 0.... Trip history clear 1.... Parameter initialization (exceptional data) b13 : Country code A53 : Rated Motor Voltage
- b16Error codeSelect how the inverter resumes operation when the free- run stop (FRS) is cancelled, two options: 0... Restart from 0Hz 1....Restart from frequency detected from real speed of motor
- b17Error codeSets the communication number for communication, range is 1 to 32
- b18Error codeSelect the function and level of ground fault.. 0 : Do not detect ground fault. 0.1~100.0% : Detect ground fault as the % level of rated current
- b20Error codeIn case of the lower starting current level during speed search motion on the basis of the motor rated current, the increase level of the output voltage is set from 10 % to 300%
- b21Error codeIn case of the higher starting current level during speed search motion on the basis of the motor rated current, the decrease level of the output voltage is set from 10 % to 300%
- b24Error codeIn case of low voltage failure, the alarm relay operation can be selected as follows 0 : Inactive incase of low voltage failure 1 : Active incase of low voltage failure
- b25Error codeYou can choose the method of stopping the motor when the inverter is given a stop command during operation. 0 : a normal decelerating stop 1 : free-run stop
- b27Error codeDetection is performed using the fluctuation in the main circuit's DC voltage. Also, in the case of degradation in the main capacitor it could be occurred where maintenance replacement is required. (0 ~ 100 in sec) When b27 equals “0”, input phase loss function is disabled
- C01Error code
- C13Error codeSelect function for terminal RN <code> 0... RUN(Run signal) 1.... FA1(Frequency arrival signal: command arrival) 2.... FA2(Frequency arrival signal: setting frequency or more) 3.... OL(Overload advance notice signal) 4.... OD(Output deviation for PID control) 5.... AL(Alarm signal)
- C15Error codeSelect function for terminal FM, 3 options 0.... output frequency monitor 1.... output current monitor 2.... output voltage monitor
- C18Error codeSets the overload signal level between 50% and 200% resolution is 0.1%.0.5x(Inverter rated current) ∼2.0x (Inverter rated current) Motor (C18) current Over load signal output
- C21Error codeSets the allowable PID loop error magnitude. Setting range is 0.0 to 100%, resolution is 0.01% Feedback value Target value PID control (C21) Deviation signal
- CD-9Error codeCoolant overheat (105ŞCŹ2ŞC) Defective overheat switch Disconnection in wiring harness or poor contact between CD-9 and CN-2(4) Disconnection in wiring harness or poor contact between CN-6(4) and CN-2(4) Defective cluster
- CN-2Error codeCoolant overheat (105ŞCŹ2ŞC) Defective overheat switch Disconnection in wiring harness or poor contact between CD-9 and CN-2(4) Disconnection in wiring harness or poor contact between CN-6(4) and CN-2(4) Defective cluster
- CN-6Error codeDefective cluster Disconnection in wiring harness or poor contact between CN-6(1) and CN-58(18) Defective check unit Disconnection in wiring harness or poor contact between CN-58(2) and CN-2(2) Disconnection in wiring harness or poor contact between CN-4(3) and CN-2(2) Disconnection in wiring harness or poor contact between CN-4(3) and alternator terminal " H " Defective alternator
- CN-7Error codeDefective cluster Disconnection in wiring harness or poor contact between CN-58(1) and fuse No.2 Disconnection in wiring harness or poor contact between CN-7(4) and fuse No.2
- CN-10Error codeDisconnection in wiring harness or poor contact between CN-10(4)- CL-3(1), 4(1) and CL-3(3) - CN-8(11), CL-4(3) - CN-8(12). Disconnection in wiring harness or poor contact between CN-10(4) and CS-11(7) Defective multifunction switch Disconnection in wiring harness or poor contact between CS-11(8) and CS-39(2) Defective head lamp switch Disconnection in wiring harness or poor contact between CS-39(4) and fuse No.19
- CN-60Error codeCause Defective cable assembly
- d01Error codeReal-time display of output frequency to motor, from 0.00 to 400.0 Hz, "Hz" LED ON
- d02Error codeReal-time display of output current to motor, from 0.0 to 999.9A, "A" LED ON
- d03Error codeReal-time display of output voltage to motor
- d13Error code
- E04Error codeThe inverter output was short-circuited. This condition causes excessive current for the inverter, so the inverter output is turned off
- E05Error codeWhen the inverter output current causes the motor to overload, the electronic thermal trip in the inverter cuts off the inverter output
- E07Error codeIf regenerative energy from the motor or the main power supply voltage is high, the protective circuit activates to cut off the inverter output when the voltage of DC link exceeds the specification
- E08Error codeThe inverter output is cut off when EEPROM in the inverter has an error due to external noise, excessive temperature rise, or other factor
- E09Error codeWhen input voltage drops below the low-voltage detection level, the control circuit does not function normally. So when the input voltage is below the specification, the inverter output is cut off
- E12Error codeWhen the external equipment or unit has an error, the inverter receives the corresponding signal and cuts off the output
- E13Error codeThe USP error is indicated when the power is turned on with the Inverter in RUN state. (Enabled when the USP function selected)
- E14Error codeWhen ground fault is detected on running condition, the output is cut off