Frigidaire All models error codes
Codes
- E5DError codeCommunication problem
- E5EError codeCommunication problem
- E5FError codeCommunication problem
- E5HError codeE5H: Motor control under voltage
- E7Error codeStuck key or fail safe mode initiated
- E8CError codeToo many trips of the safety thermostat in a period of time
- E9Error codeOpen thermistor
- E9BError codeExternal EEPROM communication or data corruption
- E9CError codeUSER INTERFACE CONFIGURATION FAULT..................189
- E9EError codeLow or intermittent voltage to board
- E9FError codeCommunication protocol
- E61Error codeHeater relay failure
- E63Error codeHeater to earth ground
- E64Error codeHeater open circuit
- E65Error codeHigh limit thermostat trip count too high
- E66Error codeHeating element relay failure
- E67Error codeInput voltage on microprocessor incorrect
- E68Error codeCurrent leakage to ground on heater or fuse opened
- E71Error codeWash NTC failure- (tub heater)
- E72Error codeOutlet control thermistor short circuit
- E73Error codeInlet control thermistor open circuit
- E74Error codeWash temperature does not increase
- E75Error codeBetter models- water temperature sensor circuit
- E76Error codeBetter models- NTC temperature for the cold water valve over the limits
- E81Error codePROGRAM SELECTOR / ENCODER FAULT....................134
- E82Error codeKey Stuck error, wiring, cycle selector switch, main board and software defect
- E87Error codeUSER INTERFACE MICROCONTROLLER FAULT..........186
- E91Error codeUser Interface to Main Control Board communication error
- E92Error codeE92: User interface and Main Board protocol incongruence error
- E93Error codeMachine configuration checksum error
- E94Error codeCycle configuration checksum error
- E95Error codeCommunication error
- E97Error codeWrong MCF data loaded cycle selector switch failure
- E98Error codeE98: Motor Control to Main Board software error
- EA1Error codePower supply frequency out of limits
- EA2Error codePower supply voltage too high
- EA3Error codePower supply voltage too low
- EA5Error codeMain voltage sensing failure
- EB2Error codeIncoming line voltage above 130VAC
- EB3Error codeIncoming line voltage below 90VAC
- EC6Error codeCLUTCH ALARM.........................................................................192
- EC7Error codeCLUTCH TRIAC SENSING FAILURE....................................193
- EF1Error codeClogged drain pump
- EF2Error codeIncorrect or excessive detergent, Drain pipe blocked or clogged
- EF3Error codeMax timeout timer
- EF5Error codeNTC temperature for the hot water valve over the limits
- EF6Error codeMain Control Board defective
- EH1Error codeAC input, Main board defective
- EH2Error code
- EH3Error code