Fresenius All models error codes
Codes
- W200Error codeBlood pump: Not stopped by operating processor
- W201Error codeFiltrate pump: Not stopped by operating processor
- W202Error codeSub pump: Not stopped by operating processor
- W203Error codeDialysate pump: Not stopped by operating processor
- W204Error codeBlood pump: Wrong speed, rate
- W205Error codeFiltrate pump: Wrong speed, rate
- W206Error codeSub pump: Wrong speed, rate
- W207Error codeDialysate pump: Wrong speed, rate
- W208Error codeBlood pump: Reed contact line threading position
- W209Error codeFiltrate pump: Reed contact line threading position
- W210Error codeSub pump: Reed contact line threading position
- W211Error codeDialysate pump: Reed contact line threading position
- W212Error codeBlood pump: Stop
- W213Error codeFiltrate pump: Stop
- W214Error codeSub pump: Stop
- W215Error codeDialysate pump: Stop
- W216Error codeBlood pump: Not stopped by safety processor
- W217Error codeFiltrate pump: Not stopped by safety processor
- W218Error codeSub pump: Not stopped by safety processor
- W219Error codeDialysate pump: Not stopped by safety processor
- W220Error codeArterial pressure: Factors / offset missing, incorrect
- W221Error codeVenous pressure: Factors / offset missing, incorrect
- W222Error codePHF pressure: Factors / offset missing, incorrect
- W223Error codeFiltrate pressure: Factors / offset missing, incorrect
- W224Error codeArterial pressure: Zero outside tolerance
- W225Error codeVenous pressure: Zero outside tolerance
- W226Error codePHF pressure: Zero outside tolerance
- W227Error codeFiltrate pressure: Zero outside tolerance
- W228Error codeArterial pressure: Detuning outside tolerance
- W229Error codeVenous pressure: Detuning outside tolerance
- W230Error codePHF pressure: Detuning outside tolerance
- W231Error codeFiltrate pressure: Detuning outside tolerance
- W232Error codeHeparin pump: does not respond
- W233Error codeHeparin pump: manually deactivated in Service program
- W234Error codeHeparin pump: detects an internal problem
- W235Error codeHeparin pump: Wrong/invalid syringe type
- W236Error codeHeparin pump: No anticoagulation
- W237Error codeHeparin pump: Anticoagulation stopped
- W238Error codeHeparin pump: Anticoagulant Used Up
- W239Error codeHeparin pump: Syringe not changed
- W240Error codeHeparin pump: Non-registered error code
- W241Error codeHeparin pump: Gate-array error
- W242Error codeHeparin pump: Restart after spike reset
- W243Error codeHeparin pump: Hex switch position error
- W244Error codeHeparin pump: Powerdown without 24V cutoff
- W245Error codeHeparin pump: Slotted disc error
- W246Error codeHeparin pump: Slotted disc not found
- W247Error codeHeparin pump: Communication sumcheck error
- W248Error codeHeparin pump: No heparin pump STOP
- W249Error codeHeparin pump: Communication error with OP