Fresenius All models error codes
Codes
- W111Error codeUpper heater: Bag sensors, OP-SP not synchronous
- W112Error codeLower heater: Bag sensor detuning, no overtemperature
- W113Error codeLower heater: Foil sensor detuning, no overtemperature
- W114Error codeUpper heater: Bag sensor detuning, no overtemperature
- W115Error codeUpper heater: Foil sensor detuning, no overtemperature
- W116Error codeLower heater: FET control defective
- W117Error codeUpper heater: FET control defective
- W118Error codeBattery test: Battery not connected, defective
- W121Error codeBlood leak detector: Outside acceptable range, remove filtrate line
- W122Error codeBlood leak detector: Alarm-free after attenuation
- W127Error codeBlood leak detector: Calibration values missing, incorrect
- W128Error codeAudible alarm: Not silenced
- W129Error codeAudible alarm: not active
- W130Error codePower failure: Emergency operation available for max. 15 minutes (OP generates code 27)
- W136Error codeBalancing, Scale I, leakage from tubing system, objects
- W137Error codeBalancing, Scale II, leakage from tubing system, objects
- W138Error codeBalancing, upper scales, leakage from tubing system, objects
- W140Error codeBalancing, filtrate scales moved, leakage from tubing system
- W141Error codeScale 1, overload or underload, check load, scale jammed?
- W142Error codeScale 2, overload or underload, check load, scale jammed?
- W143Error codeScale 3, overload or underload, check load, scale jammed?
- W144Error codeScale 4, overload or underload, check load, scale jammed?
- W145Error codeBag change: Overload on SUB scale (CVVHDF)
- W146Error codeBag change: Overload on SUB scale 1 (CVVH, HF)
- W147Error codeBag change: Overload on SUB scale 2 (CVVH, HF)
- W152Error codeBag change: Overload on plasma scale 1 (MPS)
- W153Error codeBag change: Overload on plasma scale 2 (MPS)
- W154Error codeBag change: Overload on dialysate scale (CVVHDF)
- W155Error codeBag change: Overload on dialysate scale 1 (CVVHD)
- W156Error codeBag change: Overload on dialysate scale 2 (CVVHD)
- W160Error codeBag change: Overload on filtrate scale
- W162Error codeLower heater: MPS temperature > 37°C
- W163Error codeUpper heater: MPS temperature > 37°C
- W164Error codeLower heater: Temperature too high
- W165Error codeUpper heater: Temperature too high
- W166Error codeBag change: Overload SUB pre (HVCVVH)
- W169Error codeLower heater: Foil sensors, OP-SP not synchronous
- W170Error codeUpper heater: Foil sensors, OP-SP not synchronous
- W172Error codeLower heater: MPS foil temperature too high, risk of hemolysis
- W173Error codeUpper heater: MPS foil temperature too high, risk of hemolysis
- W175Error codeBattery capacity: Charging voltage too high, battery deactivated, no power failure
- W181Error codeBalancing: Movement detected on filtrate scales, leakage from tubing system
- W182Error codeFiltrate scale: Overload or underload, check load, scale jammed?
- W184Error codeBalancing: Plasma pump delivers from wrong scale (I)
- W185Error codeBalancing: Plasma pump delivers from wrong scale (II)
- W190Error codePower failure end
- W192Error codePrime mode: Overload on dialysate scale (CVVHDF)
- W193Error codePrime mode: Overload on SUB scale (CVVHDF)
- W196Error codePrime mode: Overload on sub-scale-pre (HVCVVH)
- W197Error codePrime mode: Overload on sub-scale-post (HVCVVH)