Skip to content
RemFixitSearch fault code

Error code

Yaskawa All models code oPE09

For your safety

This fault is rated critical. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

Hazard area: brakes

If there is a risk to life, first move to a safe place, then call 112. Do not follow remote repair instructions.

Call 112

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

PID Control Selection Error

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

・The following simultaneous contradictory settings have occurred: The PID sleep function operation level (b5-15) is not set to 0.0 while the stopping method is set to either DC Injection Braking or coast to stop with a timer (b1-03 = 2 or 3). ・PID control is set to b5-01 = 1 or 2, but the lower limit for the frequency reference (d2-02) is not set to 0 while reverse output is enabled (b5-11 = 1). ・PID control is set to b5-01 = 3 or 4, but the lower limit for the frequency reference (d2-01) is not 0. ・The absolute value of the PID output lower limit is greater than the upper limit (b5-34 > b5-06)

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.