Error code
Videojet dijital baskı makinesi All models code E1539
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
(E15399) Ink Management PCB Ink Pump Supply Voltage Out of Range
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
1) Thermal event has caused F1 on the IMB to open. 2) External load on the IMB or Solvent Control Module is pulling down +24 VDC. 3) Defective Ink Pump. 4) Loss of +24 VDC from the Main Control Board (other warnings will likely be asserted). 5) Defective Ink Management PCB
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.