Error code
Vending All models code E2
No approved translation for this record yet; showing the original text.
Meaning
Display "E2" "Heating fault" Temperature sensor does not indicate nominal temperature 20 min. after the heating element has been switched on (no time limit for multibrew)
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
- Heating element calcified or defective - Water supply too cold - Temperature sensor maladjusted - Temperature sensor defective - Contact fault: heating element - Contact fault: temperature sensor - Fault in 24 V supply - Safety switch defective - Dry running protection of the boiler has been triggered or is defective - Boil over sensor has been triggered or is defective
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/vending/tum-modeller/e2