Swegon hava perdesi CFW-11 RB code F022

For your safety

This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

Hazard area: mains voltage

Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

F022 Overvoltage bar DC

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

Supply voltage too high, producing voltage on the DC bar above the maximum value: Ud > 400 V - Models 220 / 230 V (P0296 = 0). Ud > 800 V - Models 380 / 480 V (P0296 = 1, 2, 3 or 4). Ud > 1000 V - Models 500 / 600 V (P0296 = 5, 6 or 7). Ud > 1200 V - Models 660 / 690 V (P0296 = 8). ; Inertia of the driven load too high or very quick deceleration. ; P0151 too high

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.