Error code
Ruud All models code URE23
No approved translation for this record yet; showing the original text.
Meaning
TABLE 10 FILTER SIZES UPFLOW FILTER SIZES AS SHIP PART FURNACE INPUT BOTTOM NO. WIDTH BTUH SIZE 54-24094-01 14 50 121/4" X 25" 54-24094-01 171/2" 75 & 100 153/4" X 25" 54-24094-02 21" 100 191/4" X 25" 54-24094-03 241/2" 125 & 150 223/4" X 25" If high efficiency filters or electronic air cleaners are used in the system, it is important that the airflow is not reduced to maximize system performance and life. Always verify that the systems airflow is not impaired by the filtering system that has been installed, by performing a temperature rise and temperature drop test. Keep the air filters clean at all times. Vacuum dirt from filter, wash with detergent and water, air dry thoroughly and reinstall. See Table 10 and Figures 24 and 25 for proper filter sizes and locations. 1. 14”- 50,000 BTUH unit requires removal of 31/” segment of filter and 2 frame to get proper width for a bottom filter. 2. 21”-100,000 BTUH unit requires removal of 31/” segment of filter and 2 frame to get proper width for a side filter. 3. 241/”-125,000 and 150,000 BTUH 2 units require removal of 7” segment of filter and frame to get proper width for a side filter
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
TABLE 10 FILTER SIZES
Solution
Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/ruud/tum-modeller/ure23