Skip to content
RemFixitSearch fault code

Error code

Rheem All models code URE25

No approved translation for this record yet; showing the original text.

Meaning

TABLE 9 FILTER SIZES UPFLOW FILTER SIZES AS SHIPPED FURNACE INPUT BOTTOM SIDE WIDTH BTUH SIZE SIZE 14 50 121/4" X 25" 153/4" X 25 171/2" 75 & 100 153/4" X 25" 153/4" X 25 21" 100 191/4" X 25" 153/4" X 25 241/2" 125 & 150 223/4" X 25" 153/4" X 25 If high efficiency filters or electronic air cleaners are used in the system, it is important that the airflow is not reduced to maximize system performance and life. Always verify that the systems airflow is not impaired by the filtering system that has been installed, by performing a temperature rise and temperature drop test. Keep the air filters clean at all times. Vacuum dirt from filter, wash with detergent and water, air dry thoroughly and reinstall. See Table 9 and Figures 26 and 27 for proper filter sizes and locations. 1. 14”- 50,000 BTUH unit requires removal of 31/” segment of filter and 2 frame to get proper width for a bottom filter. 2. 21”-100,000 BTUH unit requires removal of 31/” segment of filter and 2 frame to get proper width for a side filter. 3. 241/”-125,000 and 150,000 BTUH 2 units require removal of 7” segment of filter and frame to get proper width for a side filter

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

TABLE 9 FILTER SIZES

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.