Error code
Phoenix Contact ev şarj istasyonu All models code I3
No approved translation for this record yet; showing the original text.
Meaning
Monitoring of charging currents - “enabled”: the charging controller compares the measured charging currents with the maximum permissible charging currents specified by the PWM signal on the Control Pilot. In the event of an overcurrent of 10% ... 20%, the charging process is aborted after 100 s. In the event of an overcurrent > 20%, it is switched off after 10 s. The charging con- troller enters an error state, the reset condition is status A. - “disabled”: no monitoring of charging currents
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberSolution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/phoenixcontactevsarjistasyonu/tum-modeller/i3