Philips ekg cihazı All models error codes
Codes
- CO2Error codeAccuracy
- D-20Error codePediatric sensor (patient size 10-50 kg)
- D-25Error codeAdult sensor (patient size >30kg)
- EC10Error codeIntelliBridge
- EC40Error codeECG
- EP1Error codeNo interruption or cessation of current operating mode (e.g. no restart)
- I-20Error codeInfant sensor (patient size 3-20 kg)
- IC1Error codePRESS
- IC2Error codePRESS
- M1131AError codeAdult/Pediatric finger sensor, 0.45m cable (patient size >20 kg)
- M1132AError codeInfant finger or toe sensor, 0.9m cable (patient size 3 - 10 kg)
- M1191AError codeAdult sensor (2m cable), for patients over 50 kg. Any finger, except thumb
- M1191TError codeAdult sensor (0.45m cable), for patients over 50 kg. Any finger, except thumb
- M1192AError codeSmall adult, pediatric sensor (1.5m cable) for patients between 15 kg and 50 kg. Any finger except thumb
- M1192TError codeSmall adult, pediatric sensor (0.45m cable) for patients between 15 kg and 50 kg. Any finger except thumb
- M1193AError codeNeonatal sensor (1.5m cable) for patients between 1kg and 4 kg. Hand or foot
- M1193TError codeNeonatal sensor (0.9m cable) for patients between 1kg and 4 kg. Hand or foot
- M1194AError codeEar sensor (1.5m cable) for patients more than 40 kg
- M1195AError codeInfant sensor (1.5m cable) for patients between 4kg and 15 kg. Any finger except thumb
- M1196AError codeAdult clip sensor (3m cable) for patients over 40 kg. Any finger except thumb
- M1196TError codeAdult clip sensor (0.9m cable) for patients over 40 kg. Any finger except thumb
- M3014AError codeAt installation, the monitor is configured to automatically apply either Body Temperature Pressure Saturated (BTPS) or Ambient Temperature Pressure Dry (ATPD). To see which, go to the Setup CO menu, and scroll down to look at Hum. Corr or 2 HumidityCorr
- M4607AError codeNominal Voltage
- M8023AError codeLine Voltage
- MP10Error codeLNCS MP Series Patient Cable (3.0 m) Adapter Cable for Masimo LNCS Sensors
- MP12Error codeLNOP MP Series Patient Cable (3.6 m) Adapter Cable for Masimo LNOP Sensors
- N-25Error codeNeonatal sensor (patient size <3 kg or >40 kg)
- O2Error codeIn the Setup CO menu, select N O Corr. If the N O correction is not available in the Setup CO menu, the CO 2 2 2 measurement in your MMS Extension does not require N O correction or it is setup 2 with Gas Corr. (see below)
- OC-3Error codeAdapter Cable for OxiCliq sensors
- P1Error codePRESS
- P2Error codePRESS
- P3Error codePPV
- T0AError codeBorderline T abnormalities, ant-lat leads.............T flat/neg, I aVL V2-V6
- T0IError codeBorderline T abnormalities, inferior leads.........T flat/neg, II III aVF
- T0LError codeBorderline T abnormalities, lateral leads.............T flat/neg, I aVL V5 V6
- T0NError codeBorderline T wave abnormalities.....T/QRS ratio < 1/20 or flat T
- T1Error codeNon-specific temperature labels
- T2Error codeMonitor
- T3Error codecerebral temperature
- T4Error codetympanic temperature
- VHR56Error codeLVH by voltage..............................R >*.***mV in V5 or V6
- VHS12Error codeLVH by voltage.......................S <*.*** in V1 or *.*** in V2
- X2Error codeOperating Voltage