Mitsubishi Electric SUZ code F5
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage and refrigerant gas circuit
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
— 63H or TRS connector open Abnormal if 63H or TRS connector circuit is open for 3 minutes continuously after power supply. • 63H: High pressure switch • TRS: Thermal protector
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
No voltage is supplied to terminal block (TB1) of the outdoor unit. a) The power supply breaker is turned off. b) Contact failure or disconnection of the power supply terminal c) Open phase (L1 or L2 phase) Electric power is not charged to the power supply terminal of the outdoor power circuit board. a) Contact failure of the power supply terminal b) Open phase on the outdoor power circuit board (Disconnection of the connector LI or NI) Electric power is not supplied to the outdoor controller circuit board. a) Disconnection of the connector (CNDC) Disconnection of the reactor (DCL) Disconnection of outdoor noise filter circuit board or parts failure in outdoor noise filter circuit board. (Type 42-60) Defective outdoor power circuit board Defective outdoor noise filter circuit board (Type 42-60) Defective outdoor controller circuit board Disconnection or contact failure of 63H or TRS connector on outdoor controller circuit board Disconnection or contact failure of 63H or TRS 63H or TRS is working due to defective parts. Defective outdoor controller circuit board