Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric SEZ code P6

No approved translation for this record yet; showing the original text.

Meaning

Freezing/overheating protection is (Cooling operating Freezing protection (Cooling mode) The unit is in 6-minute resume prevention mode if pipe <liquid or condenser/ evaporator> temperature stays under -15°C [5°F] for 3 minutes after the compressor started. Abnormal if it stays under -15°C [5°F] for 3 minutes again within 16 minutes after 6-minute resume prevention mode. Overheating protection (Heating mode) The units is in 6-minute resume prevention mode if pipe <condenser/evaporator> (Heating

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

or drying mode) Clogged filter (reduced airflow) Short cycle of air path Low-load (low temperature) operation out of the tolerance range Defective indoor fan motor • Fan motor is defective. • Indoor controller board is defective. Defective outdoor fan control Overcharge of refrigerant Defective refrigerant circuit (clogging) mode) Clogged filter (reduced airflow) Short cycle of air path Overload (high temperature) operation out of the tolerance range Defective indoor fan motor • Fan motor is defective. • Indoor controller board is defective. Defective outdoor fan control Overcharge of refrigerant Defective refrigerant circuit (restriction) Bypass circuit of outdoor unit is defective.

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.