Error code
Mitsubishi Electric PWFY code 1301
No approved translation for this record yet; showing the original text.
Meaning
Abnormal low pressure: When starting the compressor from Stop Mode for the first time if low pressure reads 0.098MPa [14psi] immediately before start-up, the operation immediately stops.
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) Inner pressure drop due to a leakage (2) Low pressure sensor failure (3) Short-circuited pressure sensor cable due to torn outer rubber (4) A pin on the male connector is missing. (5) D isconnected wire (6) Failure of the low pressure input circuit on the controller board (7) Shortage of circulating water
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Remote technician support
Get help from a technician over a video call.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/pwfy/1301