Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PUZ code 4400

For your safety

This fault is rated critical. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

Hazard area: mains voltage and refrigerant gas circuit

If there is a risk to life, first move to a safe place, then call 112. Do not follow remote repair instructions.

Call 112

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

Detailed: The outdoor fan motor is considered to be abnormal if the rotational frequency of fan motor is abnormal when detected during operation. Fan motor rotational frequency is abnormal if; • 100 rpm or below detected continuously for 15 seconds at 68˚F [20:] or more outside air temperature • 50 rpm or below or 1500 rpm or more detected continuously for 1 minute. To find out the detail history (latest) codes Refer to "10-10. FUNCTION OF SWITCHES, Overvoltage error • Increase in DC bus voltage to 400 V

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Abnormal increase in power source voltage (2) Disconnection of compressor wiring (3) Defective outdoor power circuit board (4) Compressor has a ground fault.

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.