Mitsubishi Electric PUZ code 1300

No approved translation for this record yet; showing the original text.

Meaning

Low pressure Abnormal if the following conditions are detected for continuously 3 minutes after compressor starts heating operating for 10 minutes. 1. Heating mode Detection mode 1 TH7−TH3 4°C and [ TH5−Indoor room temperature 2°C [ Detection mode 2 TH7−TH3 2°C and [ TH5−Indoor room temperature [ 4°C and TH2−Indoor room temperature 4°C [ Detection mode 3 TH7−TH3 [ 4°C and TH5−Indoor room temperature 2°C [ and TH4−TH5 ] 20°C 2. Cooling mode TH6−TH7 2°C and [ TH3−TH7 [ 2°C and Indoor room temperat

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Stop valve of outdoor unit is closed during operation. (2) Leakage or shortage of refrigerant (3) Malfunction of linear expansion valve (4) Clogging with foreign objects in refrigerant circuit Note: If water enters in refrigerant circuit, clogging may occur where the part becomes below freezing point.

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.