Error code
Mitsubishi Electric PUY code 6607
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage and refrigerant gas circuit
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
System composition system refrigerant Single (1): No ACK abnormality Generating Detecting Display of unit method trouble address 1. Outdoor Remote No reply unit(OC) controller (ACK) at BC (RC) transmission to OC 2. Indoor Remote No reply unit (IC) controller (ACK) at RC (RC) transmission to IC 3. Remote Remote No reply controller controller (ACK) at IC (RC) transmission (RC) to RC Meaning, | (continued) System composition refrigerants plural using system operation Group (2): No ACK abnormality Generating Detecting Display of unit method trouble address 1. Outdoor Remote No reply unit(OC) controller (ACK) at BC (RC) transmission to OC 2. Indoor Remote No reply unit (IC) controller (ACK) at RC (RC) transmission to IC 3. Remote Remote No reply controller controller (ACK) at IC (RC) (RC) transmission to RC Meaning, | (continued) Generating System composition 1. 2. (MELANS) controller with system Connecting (3): No ACK abnormality When interval error. Display of Detecting unit trouble method address Outdoor Remote No reply unit(OC) controller (ACK) at BC (RC) transmission to OC Indoor Remote No reply unit (IC) controller (ACK) at (RC) transmission of SC to IC Meaning, | (continued) Generating System composition 3. (MELANS) controller with system Connecting (3): No ACK abnormality When interval error. Display of Detecting unit trouble method address Remote Remote No reply controller controller (ACK) at (RC) (RC) transmission of IC to RC No reply (ACK) at transmission of MELANS to R
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
When no ACK signal is detected in 6 interval by transmission side controller, error. Note : The address/attribute shown controller not providing the Cause (1) Poor contact of transmission line of OC or BC. (2) Damping of transmission line voltage/signal by acceptable range of transmission wiring exceeded. Farthest: Less than 200m Remote controller wiring: Less than 10m (3) Erroneous sizing of transmission line (Not within the range below). Wire diameter: 1.25mm2 or more (4) Faulty control circuit board of OC. (1) When IC unit address is changed or modified during operation. (2) Faulty or disconnection of transmission wiring of IC. (3) Disconnection of IC unit connector (CN2M). (4) Faulty IC unit controller. (5) Faulty remote controller. (1) Faulty transmission wiring at IC unit side. (2) Faulty transmission wiring of RC. (3) When remote controller address is changed or modified during operation. (4) Faulty remote controller. detecting method As same that for single refrigerant system. (1) Cause of (1) ~ (5) of “Cause for single refrigerant system”. (2) Disconnection or short circuit of transmission line of OC terminal block for centralized control (TB7). (3) Shut down of OC unit power source of one refrigerant system. (4) Neglecting insertion of OC unit power supply connector (CN40). (5) Inserting more than 2 sets of power supply connector (CN40) for centralized control use. For generation after normal operation conducted once, the following causes can be considered. • Total
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/puy/6607