Mitsubishi Electric PUY code 1500

No approved translation for this record yet; showing the original text.

Meaning

Overcharged refrigerant abnormality: 1. If the discharge SH 10K is detected during operation (at first detection), the outdoor unit stops at once. The 3 minutes restart prevention mode is entered. After three minutes, the outdoor unit starts up again. 2. If the discharge SH 10K is detected again within 30 minutes after the outdoor unit stops (second detection), an abnormal stop is applied, and “1500” is displayed. 3. If discharge SH 10K is detected more than 30 minutes after the outdoor unit stops, the state is the same as the firs

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Excessive refrigerant charge. (2) Main circuit board thermistor input circuit trouble. (3) Thermistor mounting trouble (TH11, TH12).

Solution

Solution steps are not shared for faults that may be dangerous.