Error code
Mitsubishi Electric PURY code 6608
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
No response When no response command is returned although acknowledgement (ACK) is received after transmission, an error is detected. When the data is transmitted 10 times in a row with 3 seconds interval, an error is detected on the transmission side. Note:The address/attribute appeared on the display on the remote controller indicates the controller where an error occurred. | No response When no response command is returned although acknowledgement (ACK) is received after transmission, an error is detected.When the data is transmitted 10 times in a row with 3 seconds interval, an error is detected on the transmission side. Note: The address/attribute appeared on the display on the remote controller indicates the controller where an error occurred.
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) The transmission line work is performed while the power is on, the transmitted data will collide, and the wave shape will be changed. (2) The transmission is sent and received repeatedly due to noise. Farthest : 200m [656ft] or less Remote controller wiring: 12m [39ft] or less (4) The transmission line voltage/ signal is decreased due to erroneous sizing of transmission line. 1.25mm2 Wire diameter: [AWG16] or more (1) The transmission line work of one of the indoor unit, outdoor unit, or the BC controller is performed while the power is on, the transmitted data will collide, and the wave shape will be changed. (3) The transmission line voltage/ signal is decreased due to erroneous sizing of transmission line. Farthest: 200 m [656ft] or less Remote controller wiring:} 10m [32ft] or less (4) The transmission line voltage/ signal is decreased due to erroneous sizing of transmission line. Wire diameter: 1.25mm2 [AGW16] or less
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/pury/6608