Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PURY code 6606

For your safety

This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

Hazard area: mains voltage

Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

Communication error with the transmission processor Communication error between the main microcomputer on the indoor unit board and the microcomputer for transmission Note: The address/attribute appeared on the display on the remote controller indicates the controller where an error occurred. Error | Communication error with the transmission processor Communication error between the main microcomputer on the indoor unit board and the microcomputer for transmission Note: The address/attribute appeared on the display on the remote controller indicates the controller where an error occurred.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Data is not properly transmitted due to accidental erroneous operation of the controller of the error source. (2) Error source controller failure definition and error detection method Error definition and error detection The error is detected when no acknowledgement transmission. (eg. When the data interval, the error is detected on Note: The address/attribute appeared indicates the controller Cause (1) Contact failure of transmission line of OC or BC (2) Decrease of transmission line voltage/signal by exceeding ceptable range of transmission to wiring . Farthest : 200 m [656ft] or less Remote controller wiring: 10m [32ft] or less (3) Erroneous sizing of transmission line (Not within the range below). 1.25mm2 Wire diameter: [AWG16] or more (4) Indoor unit main board failure (5) Power circuit failure of outdoor unit (1) When BC controller address is changed or modified during operation. (2) Faulty or disconnected transmisIC sion wiring of BC controller (3) Disconnected connector of BC controller (CN02) (4) Faulty control board of BC controller (1) When IC unit address is changed or modified during operation. (2) Faulty or disconnected IC transmission wiring to (3) Disconnected IC connector (CN2M) (4) Indoor unit board failure (5) M-NET remote controller failure (1) The power source of LOSSNAY has been shut off. (2) When the address of LOSSNAY changed in the middle of the operIC ation (3) Faulty or disconnected transmission wiring of LOSSNAY (4) Disconnected connector (CN1)

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.