Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PUHZ code 7130

No approved translation for this record yet; showing the original text.

Meaning

Reverse connection of ATA/ATW communication wire Abnormal if communication wire of ATA side and FTC side are connected in reverse.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Each S1, S2, S3 of TB1 and TB2 are connected in reverse. (2) The connection from TB1 and TB2 to indoor controller board CNS and CNS2 are in reverse.

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.