Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PUH code UE

No approved translation for this record yet; showing the original text.

Meaning

Abnormal High pressure This error is detected (4.14MPa) from 63H action within 20 seconds of compressor starting in the first heating mode after power on. 63H: high-pressure switch

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Gas pipe side ball valve and liquid pipe side stop valve are shut during operation. (2) Disconnection or contact failure of 63H (3) Defective outdoor controller board (4) Power supply reset is detected while indoor filter clogs and overload heating operation. (5) Defective outdoor controller board (6) Defective action of linear expansion valve

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.

Remote technician support

Get help from a technician over a video call.