Mitsubishi Electric PUH code FA

No approved translation for this record yet; showing the original text.

Meaning

51CM connector open Abnormal if 51CM connector circuit is open for 3 minutes continuously after power on. 51CM: Thermal Relay

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Disconnection or contact failure of 51CM connector on outdoor controller board (2) Disconnection or contact failure of 51CM (3) Defective 51CM (defective parts) (4) Defective outdoor controller