Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PUH code F9

No approved translation for this record yet; showing the original text.

Meaning

2 or more connectors open Abnormal if two more out of connector (63L, 51CM) circuits are open for 3 minutes continuously after power on.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Disconnection or contact failure of connector (63L, 51CM) on outdoor controller board (2) Disconnection or contact failure of (63L, 51C) (3) Defective (63L, 51C) (defective parts) (4) Defective outdoor controller board

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.