Error code
Mitsubishi Electric PUH code 4101
For your safety
This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.
Hazard area: mains voltage and refrigerant gas circuit
Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.
The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.
No approved translation for this record yet; showing the original text.
Meaning
Compressor over current (overload) breaking Abnormal if current value exceeds overload set value during compressor operation. P71V• 23.5A P71Y• 7.8A • • • • P100V• 28.5A P100Y• 9.4A • • • • P125Y• 12.6A P140Y• 15.6A • • • • | Thermal relay (51C) worked Abnormal if 51C is open.
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) Gas pipe side ball valve and liquid pipe side stop valve are shut during operation. (2) Abnormal compressor (3) Abnormal power supply voltage (4) Overload operation (1) Ball valve and stop valve are closed during operation.
Solution
Solution steps are not shared for faults that may be dangerous.
No do-it-yourself solution is given for this fault. For your safety, call an authorised service.
Address of this page: https://www.remfixit.com/tr/mitsubishi-electric/puh/4101