Error code
Mitsubishi Electric PFD code 6834
No approved translation for this record yet; showing the original text.
Meaning
MA controller signal reception error (Start bit detection error): Communication between the MA remote controller and the indoor unit is not done properly. No proper data has been received for 2 minutes.
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) Contact failure of the remote controller lines of MA remote controller or the indoor unit. (2) All the remote controllers are set to SUB. (3) Failure to meet wiring regulations Wire length Wire size Number of remote controllers Number of indoor units (4) The remote controller is removed after the installation without turning the power source off. (5) Noise interference on the remote controller transmission lines (6) Faulty circuit that is on the indoor board and performs transmission/ reception of the signal from the remote controller (7) Problems with the circuit on the remote controller that sends or receives the signals from the remote controller
Solution
Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.
Remote technician support
Get help from a technician over a video call.