Mitsubishi Electric PFD code 4230

No approved translation for this record yet; showing the original text.

Meaning

Radiator panel overheat protection: If the cooling fan stays ON for 5 minutes or longer during inverter operation, and 100°C if THHS is detected.

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) The wiring is defective. (2) The INV boar’s fuse (F01) is defective. (3) The cooling fan (MF1) is defective. (4) The THHS sensor is defective. (5) The air passage is clogged. (6) The IPM is defective. (7) The circuit board is defective.

Solution

Solution steps are available to members and are not shown on this page. Answer the questions to open the solution.

Remote technician support

Get help from a technician over a video call.