Meaning
Low pressure saturation temperature sensor abnormality (TH2): 1. When saturation temperature sensor (TH2) or liquid level detecting temperature sensors (TH3, TH4) detects -40˚C or less (the first time) during operations, outdoor unit stops once, mode is changed to restart mode after 3 minutes, then the outdoor unit restarts. 2. When -40˚C or less temp. is detected again (the second time) within 30 minutes after stop of outdoor unit, error stop is observed with code Nos. “1111,” “1112,” or “1113” displayed.
Member details
Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.
View details as a memberPossible causes
(1) Gas leak, Gas shortage. (2) Insufficient load operations. (3) Poor operations of indoor LEV. (4) Poor operations of OC controller LEV: (5) Setting error of connection address.
Solution
Solution steps are not shared for faults that may be dangerous.