Meaning

Compressor and indoor fan will be turned off. Drain pump is abnormal if the condition 2 above is detected during suspensive abnormality. Constantly detected during drain pump 3 operation

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Malfunction of drain pump (2) Defective drain Clogged drain pump Clogged drain pipe (3) Defective drain float switch Catch of drain float switch or malfunction of moving parts cause drain float switch to be detected under water (Switch On) (4) Defective indoor-controller board

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.