Skip to content
RemFixitSearch fault code

Error code

Mitsubishi Electric PCA code 2500

For your safety

This fault is rated high and involves an area that affects personal safety. No remote repair or do-it-yourself instructions are given; do not use the appliance or try to open or repair it.

Hazard area: mains voltage and refrigerant gas circuit

Do not use the appliance and call an authorised service. If there is a risk to life, move to a safe place and see the emergency numbers.

The emergency numbers here are for Turkey. If you are outside Turkey, call your local emergency number.

All emergency numbers and province details

No approved translation for this record yet; showing the original text.

Meaning

(Drain pump will start operating when the drain sensor detects to be soaked in the water.) The unit has a water leakage abnormality 2 when the following conditions, a) and b), are satisfied while the above-mentioned detection is performed. a) The drain s

Member details

Signed-in members see the LED pattern and how to read the code with the remote control on eligible records.

View details as a member

Possible causes

(1) Drain pump trouble (2) Drain defective · Drain pump clogging · Drain pipe clogging (3) Open circuit of drain sensor side heater (4) Contact failure of drain sensor connector (5) Dew condensation on drain sensor · Drain water trickles along lead wire. Note: Refer to the manual of outdoor board is also off. is not supplied to outCheck 1 supply • check and • circuit board Check 2 terminal • —check • is not supplied to indoor Check 3 block • check wire • board Check 4 power • • board Check 5 indoor board. board. address for outdoor unit corresponding to refrigerant indoor controller board is also blinking. of indoor/outdoor unit connecting controller wires system, 2 indoor units are wired for outdoor unit is wrong or not control system, there are some units address is 0. controller wires controller downward during defrosting and and when the thermostat is OFF in of COOL protection function) not rotate. motor or connection failure of connector vane setting is “No vanes”. vane does not work. to

Solution

Solution steps are not shared for faults that may be dangerous.

No do-it-yourself solution is given for this fault. For your safety, call an authorised service.